Delem
V1101, 9.30
Potentiometer nr.
Function
Start position
RP1
offset feedback
minimal = completely turned
to the right
RP2
gain feedback
maximal = completely turned
to the left
RP4
gain braking on Y-brake
minimal = completely turned
to the left
RP5
slip factor
minimal = completely turned
to the left
RP6
gain differential
minimal = completely turned
to the left
C
The potentiometers RP3, RP7, RP8, RP9 and RP10 are factory set to optimal values.
Adjustment procedure part support
C
Go to the diagnostic mode
C
Select DM01 module that controls the part support.
C
Move cursor to the speed output parameter ‘output0' with cursor key.
C
Select 0 (= 0%).
C
Start the machine and the hydraulic pump of the part support construction.
C
Follow the next adjustment procedures:
**
Adjustment of the feedback offset (see O1 in the blockdiagram of principle PID-
controller)
C
Turn RP1 until the part support is in the horizontal position.
In case the part support can not be adjusted in an optimal way turn potentiometer RP6 a
couple of turns to the right.
**
Adjustment of the feedback gain (see A1 in the blockdiagram of principle PID-
controller)
C
Select 50% of ‘output0'. This corresponds with the value 127.
C
Turn potentiometer RP2 until the part support brackets are exactly halfway the maximum
required angle.
**
Adjustment of the differential gain (see A3 in the blockdiagram of principle PID-
controller)
C
Leave the diagnostic program.
C
Program the part support machine parameters before continuing this procedure. See
section 9.3.
C
Select the manual mode.
C
Program the manual mode parameters and program the pressing speed not too high, e.g. 2
mm/s.
C
Make some pressing movements and turn potentiometer RP6 during the pressing phase
so, that the part support is not oscillating and following the pressing movement fluently.
**
Adjustment of the slipfactor (differentiating gain D in the blockdiagram of principle PID-
controller)
Summary of Contents for DA-65
Page 1: ...Delem V0303 MACHINE PARAMETERS MANUAL DA 65 V7 DA 69 V7 DA 68PL V7 DA on Windows V1...
Page 17: ...Delem V1101 1 6...
Page 55: ...Delem V1101 3 16 Parameter 16 19 Not used...
Page 67: ...Delem V1101 3 28 Parameter 28 Not used...
Page 68: ...Delem V1101 3 29 Parameter 29 Not used...
Page 79: ...Delem V1101 3 40 Parameter 40 41 Not used...
Page 81: ...Delem V1101 3 43 Parameter 43 45 Not used...
Page 89: ...Delem V1101 3 53 Parameter 53 Not used...
Page 94: ...Delem V1101 3 58 Parameter 58 Not used...
Page 96: ...Delem V1101 3 60 Parameter 60 119 Not used...
Page 175: ...Delem V1101 6 5 6 4 Crowning parameters Figure 6 4 a...
Page 197: ...Delem V1101 8 3 8 3 Digital I axis parameters Figure 8 3 a...
Page 207: ...Delem V1101 9 5 Figure 9 2 c Figure 9 2 d...
Page 239: ......