Delem
V1101, 5.35
Parameter 13:
Acceleration ramp
Range
: 5 - 1275
Default
: 160
Units
:
ms
Function
Acceleration ramp for the connected axis.
Description
This parameter defines the time needed to reach the full speed output. An acceleration ramp
means that when the axis starts moving to a new position the speed signal increases with a
certain ramp until the maximum needed speed has been reached.
Figure 5.3.e