Delem
V1101, 9.35
Parameter: NR
Nr. of Units
Range
: 1 - 4
Default
:
1
Unit
:
-
Function
The number of part support arms that can be controlled.
Description
In the default situation you require one DBT01 card with which one part support arm is
controlled with Y-brake feedback to the DM01 module.
For each extra part support axis you require a separate DBT01 control card. Two or more part
support arms can be controlled in two ways:
C
Synchronised. In this case all part support arms are used or are not used: together ‘On’ or
together ‘off’. The Y-brake feedback of the latest DBT01 is connected to the DM01
module. See also connection diagram dual part support as an example of two
synchronised part support arms.
Program ‘Number of units’ for synchronised control always the value 1.
C
Separate. In this case you can specifiy which part support arms should be used or not. To
control the part support arms separately you have to program some flags in the
sequencer program. The control data for each part support arm should be matched on a
digital output on the DM01. These digital outputs have to be connected to the DBT01
output (C18) to disable the control of the valve card or the motor drive. The Y-brake
feedback may not be connected in this case!
See also the ‘Delem Sequencer Programming Language’ manual for information about
programming the sequencer for driving separate part support arms.
Program ‘Number of units’ for separate control equal to the number of part support
arms.
Summary of Contents for DA-65
Page 1: ...Delem V0303 MACHINE PARAMETERS MANUAL DA 65 V7 DA 69 V7 DA 68PL V7 DA on Windows V1...
Page 17: ...Delem V1101 1 6...
Page 55: ...Delem V1101 3 16 Parameter 16 19 Not used...
Page 67: ...Delem V1101 3 28 Parameter 28 Not used...
Page 68: ...Delem V1101 3 29 Parameter 29 Not used...
Page 79: ...Delem V1101 3 40 Parameter 40 41 Not used...
Page 81: ...Delem V1101 3 43 Parameter 43 45 Not used...
Page 89: ...Delem V1101 3 53 Parameter 53 Not used...
Page 94: ...Delem V1101 3 58 Parameter 58 Not used...
Page 96: ...Delem V1101 3 60 Parameter 60 119 Not used...
Page 175: ...Delem V1101 6 5 6 4 Crowning parameters Figure 6 4 a...
Page 197: ...Delem V1101 8 3 8 3 Digital I axis parameters Figure 8 3 a...
Page 207: ...Delem V1101 9 5 Figure 9 2 c Figure 9 2 d...
Page 239: ......