Parameter 26:
Output min.
Range
:
0-255
Default
:
48
Units
:
DA-points
Function
Pressure valve deflection for minimal force.
Description
Output deflection for proportional pressure valve in DA-points to give min.force.
There are two ranges of pressure valves:
•
800 mA. These valves can be programmed to max 136 DA-points.
•
1500 mA. These valves can be programmed to max 255 DA-points.
See also calibration procedure with machine parameter Calibration.