To build a spindle correction table, a plain ASCII text file must be created with table values as
follows:
;VERSION: Example-X
;CONFIG: X: C
X10 C0.5
X500 C1.0
X1000 C2.6
In this example, three setpoints are defined for the X-axis. The ‘VERSION’ statement on the
first line can be used to define a name or version for the table, but this is not compulsory.
The ‘CONFIG’ statement must be used to define the format of table entries. On the lines that
follow, the actual table entries are written.
A spindle correction table can be loaded from floppy. To be able to recognise a table for a
certain axis, each table has a unique filename, 'spcorXX.tab'. In this name, 'XX' must be replaced
by the index number of the required axis.
The following axis numbers can be used in filenames for tables:
00 X-axis
01 R-axis
02 R1-axis
03 R2-axis
06 Z-axis
09 Z1-axis
10 Z2-axis
13 I-axis
15 X2-axis
17
general purpose, X3-axis
18
general purpose, X4-axis
19
general purpose, X1-axis
20
general purpose, X2-axis
21 Part
support
40 R3-axis
41 R4-axis
A table can be loaded in the parameter menu of the appropriate axis. In this menu the softkey
‘load cor. table’ is available. When pressed, the control will search for a valid file in the floppy
drive. If loading was succesfull, the string ‘SpCor.:’ will appear in the top row followed by the
name or version of the table, if present in the textfile. If loading was not succesfull, the message
‘File does not exist’ is displayed.
A loaded correction table can also be erased with the softkey ‘delete cor. table’. This softkey
appears automatically after a table has been loaded.
Summary of Contents for DA-65
Page 1: ...Delem V0303 MACHINE PARAMETERS MANUAL DA 65 V7 DA 69 V7 DA 68PL V7 DA on Windows V1...
Page 17: ...Delem V1101 1 6...
Page 55: ...Delem V1101 3 16 Parameter 16 19 Not used...
Page 67: ...Delem V1101 3 28 Parameter 28 Not used...
Page 68: ...Delem V1101 3 29 Parameter 29 Not used...
Page 79: ...Delem V1101 3 40 Parameter 40 41 Not used...
Page 81: ...Delem V1101 3 43 Parameter 43 45 Not used...
Page 89: ...Delem V1101 3 53 Parameter 53 Not used...
Page 94: ...Delem V1101 3 58 Parameter 58 Not used...
Page 96: ...Delem V1101 3 60 Parameter 60 119 Not used...
Page 175: ...Delem V1101 6 5 6 4 Crowning parameters Figure 6 4 a...
Page 197: ...Delem V1101 8 3 8 3 Digital I axis parameters Figure 8 3 a...
Page 207: ...Delem V1101 9 5 Figure 9 2 c Figure 9 2 d...
Page 239: ......