Delem
V0802, 3.15
Parameter 15:
Calibrate valves 1/0
Range
:
0-1
Default
:
0
Units
:
-
Function
To adjust the valve offset of the servo valves in the manual mode (not for Hoerbiger hydraulics
application).
Description
For valve types that use the ±10V output of the DM02, there are two ways to adjust the offset:
•
In the diagnostic mode (without using this parameter).
It is possible to adjust the offset of these valves on the valve deflection page in the DM02
module test menu. If the cursor on the screen is set at one of the offsets, it can be adjusted
using the handwheel. The range is between -127 and +127. This corresponds with an offset
in the range between -600 and +600 mV.
•
In the manual mode.
It is also possible to adjust the position of the beam in manual mode with the handwheel. The
best way to do this is during the dwell time (status 4) and by programming a long dwell time.
This adjustment mode must be enabled with this machine parameter.
When you have programmed this parameter to ‘1’, the sofkey ‘Y1/Y2 cal. select’ appears in the
manual mode. With this softkey you select Y1 or Y2 for offset adjustment. The selected side is
highlighted on the service row. The selected side can now be adjusted with the handwheel. The
corresponding valve offset will be memorized in the DM02 when the other side is selected or on
exit of the manual mode.
After the offset adjustment has been finished, this parameter must be reset to zero again.
Press the key
to select the required setting.
Note 1
Offset adjustment for Hoerbiger valves must always be adjusted in the diagnostic program. They
cannot be adjusted with the manual mode.
Summary of Contents for DA-65
Page 1: ...Delem V0303 MACHINE PARAMETERS MANUAL DA 65 V7 DA 69 V7 DA 68PL V7 DA on Windows V1...
Page 17: ...Delem V1101 1 6...
Page 55: ...Delem V1101 3 16 Parameter 16 19 Not used...
Page 67: ...Delem V1101 3 28 Parameter 28 Not used...
Page 68: ...Delem V1101 3 29 Parameter 29 Not used...
Page 79: ...Delem V1101 3 40 Parameter 40 41 Not used...
Page 81: ...Delem V1101 3 43 Parameter 43 45 Not used...
Page 89: ...Delem V1101 3 53 Parameter 53 Not used...
Page 94: ...Delem V1101 3 58 Parameter 58 Not used...
Page 96: ...Delem V1101 3 60 Parameter 60 119 Not used...
Page 175: ...Delem V1101 6 5 6 4 Crowning parameters Figure 6 4 a...
Page 197: ...Delem V1101 8 3 8 3 Digital I axis parameters Figure 8 3 a...
Page 207: ...Delem V1101 9 5 Figure 9 2 c Figure 9 2 d...
Page 239: ......