Delem
V1101, 6.4
DA-max. =
185
Note: The unit indication "mm" will not be displayed on the screen (data preparation and data
editing) of the control.
Crowning device position and adjustment for non calculated purposes
When you use the non calculated crowning device the required crowning is not based on the
three machine parameters, as described before. You have to program the required value.
To be sure that the crowning device is adjusted to the programmed position. The crowning
device should be adjusted as follows:
•
Go to to the auxiliary menu and program axis ‘CROWN’.
•
Press ‘change parameters’.
•
Program for Min. value and DA-min 0.
•
Program for Max. value and DA-max 255 (standard resolution) and 1023 (high resolution).
•
Move the crowning device to the mechanical minimal position by means of the handwheel or
to the position that corresponds with 0 % crowning.
•
Read out the deflection value on the screen (Manual mode, manual positioning). This value
corresponds with the number of DA-points. Remember that value and program it at the end
of the adjustment procedure at the parameter DA-min.
•
Now move the crowning device to the mechanical maximal position or to the position that
corresponds with 100% crowning.
•
Read out the deflection value on the screen (Manual mode, manual positioning). This value
corresponds with the number of DA-points. Remember the value and program it at the end of
the adjustment procedure at the parameter DA-max.
•
Program now the found DA-values to the corresponding machine parameters and program
Min. Value at 0 (read 0 %) and Max. Value at 100 (read 100 %).
Summary of Contents for DA-65
Page 1: ...Delem V0303 MACHINE PARAMETERS MANUAL DA 65 V7 DA 69 V7 DA 68PL V7 DA on Windows V1...
Page 17: ...Delem V1101 1 6...
Page 55: ...Delem V1101 3 16 Parameter 16 19 Not used...
Page 67: ...Delem V1101 3 28 Parameter 28 Not used...
Page 68: ...Delem V1101 3 29 Parameter 29 Not used...
Page 79: ...Delem V1101 3 40 Parameter 40 41 Not used...
Page 81: ...Delem V1101 3 43 Parameter 43 45 Not used...
Page 89: ...Delem V1101 3 53 Parameter 53 Not used...
Page 94: ...Delem V1101 3 58 Parameter 58 Not used...
Page 96: ...Delem V1101 3 60 Parameter 60 119 Not used...
Page 175: ...Delem V1101 6 5 6 4 Crowning parameters Figure 6 4 a...
Page 197: ...Delem V1101 8 3 8 3 Digital I axis parameters Figure 8 3 a...
Page 207: ...Delem V1101 9 5 Figure 9 2 c Figure 9 2 d...
Page 239: ......