Delem
V1101, 8.5
Parameter LS:
Ls FD output
Range
: 1 - 5
Default
: 3
Units
:
-
Function
To determine the least significant digital function output. There are five digital function outputs.
F1 and F2 are used by the digital R-axis, if available. Therefore the default value is 3 (=F3).
Depending on the Number of positions of the digital I-axis you require one or two digital
outputs.
In case you require two digital outputs these digital outputs have to be in succession. In this case
the value of the least significant FD output can never be 5.