Delem
V0802, 3.4
Parameter 4:
Y-dir/- (1/0)
Range
:
0-1
Default
:
1
Units
:
-
Function
Y-axis counting direction
Description
When you have programmed ‘1', the Y-axis value on the user screen counts up when the beam
closes. When you have programmed ‘0', the Y-axis value on the user screen counts down when
the beam closes.
Press the key
to select the required setting.
Note
The definition of all the Y-axis machine parameters such as ‘Y-max’ and ‘Y-min’ is always in
the count up direction.
Example
Y-max = 150.00 mm
Y-min = 10.00 mm
Figure 4.a