Delem
V1101, 4.18
Projection method
With the projection method, the exact gauge positions of the two fingers must be entered in a
similar pop-up screen in user mode. Both X- and Z- values refer to the finger positions. The
resulting axes values will be calculated from these finger positions.
In the case of a crossbeam system, axis values will be calculated from the position co-ordinates.
In the case of a console system, the gauges co-ordinates and the axis values are identical. Hence
there is not much sense in using the projection method with a console type system: axis values
can be programmed directly in data edit mode anyway.
Figure 4.6.c