Delem
V0802, 4.15
Parameter: 9 - 12
Distance A-D
Range
: 0 - 9999
Default
:
0
Units
:
mm
Function
Dimensions of a crossbeam backgauge system.
Description
These four distances are used to describe the geometry of the machine in case a crossbeam is
used.
The meaning of these dimensions is:
A:
Length of fingers measured perpendicular from the turning point of the Z-axes to the end
of the fingers.
B:
Distance between the turning points of the crossbeam.
C:
Z1-axis position of the left turning point of the crossbeam.
D:
Radius of the end of the finger (0=no radius).
Figure 4.5.d