Delem
V1101, 1.4
1.4 X-axis
signals
Symbol
Function
R-in
R-axis positive input. This input must be active (+24V) to have the X-axis
moving within the safety zone of the applied die. Otherwise the X-axis will not
move within this zone and as a result the CNC-RDY output will never become
active!
When the R-axis is negative and the R-in input is active, the R-axis will first
move to a positive position before the X-axis will move to a position within the
safety zone.
Figure 1.4.a
1.5 Axis
signals
Symbol Function
INPOS
This output is active when the actual position value of the axis is within the in
position tolerance range of the programmed position. This in position tolerance
range can be set with the machine parameter ‘In position tolerance’ (parameter
12).
START Input for an axis module, to signal that equipment is ready and the module can
start positioning the axis. Can be used to monitor ‘ready’ signal from a motor
drive.
RSD
For taking the reference marker from the encoder you must connect this input
to the reference search direction switch. The reference search cycle is then as
described at the machine parameter 17 (RSD-switch). Usually the RSD input is
taken from the End Of Travel switch.
When you use an RSD-switch for reference search the motor drive does not need any direction
sensitive enable/disable input for reference search. You are also free to place this switch
anywhere you want. You can also combine the RSD-switch with one of the EOT switches.
Summary of Contents for DA-65
Page 1: ...Delem V0303 MACHINE PARAMETERS MANUAL DA 65 V7 DA 69 V7 DA 68PL V7 DA on Windows V1...
Page 17: ...Delem V1101 1 6...
Page 55: ...Delem V1101 3 16 Parameter 16 19 Not used...
Page 67: ...Delem V1101 3 28 Parameter 28 Not used...
Page 68: ...Delem V1101 3 29 Parameter 29 Not used...
Page 79: ...Delem V1101 3 40 Parameter 40 41 Not used...
Page 81: ...Delem V1101 3 43 Parameter 43 45 Not used...
Page 89: ...Delem V1101 3 53 Parameter 53 Not used...
Page 94: ...Delem V1101 3 58 Parameter 58 Not used...
Page 96: ...Delem V1101 3 60 Parameter 60 119 Not used...
Page 175: ...Delem V1101 6 5 6 4 Crowning parameters Figure 6 4 a...
Page 197: ...Delem V1101 8 3 8 3 Digital I axis parameters Figure 8 3 a...
Page 207: ...Delem V1101 9 5 Figure 9 2 c Figure 9 2 d...
Page 239: ......