Delem
V1101, 3.24
Parameter 24:
Force min.
Range
:
0-32000
Default
:
100
Units
: kN
Function
Minimal tonnage of press brake.
Description
Minimal tonnage of the press brake is used to compute the pressure valve output deflection. It is
also used to check the programmed force value. When the start button is pressed and the
programmed force is less than force min, the force is limited at force min. See also calibration
procedure described with machine parameter calibration.