Delem
V1101, 3.23
Parameter 23:
Force max.
Range
:
0-32000
Default
:
1100
Units
: kN
Function
Maximal tonnage of press brake
Description
Maximal tonnage of the press brake is used to compute the pressure valve output deflection. It is
also used to check the programmed and computed values for the force. If the computed force is
greater than force max. the following error message will be displayed on the screen.
** computed force > force max. **
The message can also appear when the decompression distance is computed because the control
needs to compute the force before computing the decompression. When the start button is
pressed in manual mode or automatic mode, and the programmed force > force max then the
following error message will appear on the screen.
** programmed force > force max. **
The value programmed for force is limited at force max. See also calibration procedure
described with machine parameter calibration (parameter 22).
Summary of Contents for DA-65
Page 1: ...Delem V0303 MACHINE PARAMETERS MANUAL DA 65 V7 DA 69 V7 DA 68PL V7 DA on Windows V1...
Page 17: ...Delem V1101 1 6...
Page 55: ...Delem V1101 3 16 Parameter 16 19 Not used...
Page 67: ...Delem V1101 3 28 Parameter 28 Not used...
Page 68: ...Delem V1101 3 29 Parameter 29 Not used...
Page 79: ...Delem V1101 3 40 Parameter 40 41 Not used...
Page 81: ...Delem V1101 3 43 Parameter 43 45 Not used...
Page 89: ...Delem V1101 3 53 Parameter 53 Not used...
Page 94: ...Delem V1101 3 58 Parameter 58 Not used...
Page 96: ...Delem V1101 3 60 Parameter 60 119 Not used...
Page 175: ...Delem V1101 6 5 6 4 Crowning parameters Figure 6 4 a...
Page 197: ...Delem V1101 8 3 8 3 Digital I axis parameters Figure 8 3 a...
Page 207: ...Delem V1101 9 5 Figure 9 2 c Figure 9 2 d...
Page 239: ......