Delem
V1101, 9.25
Requirements and recommendations for part support systems
The following remarks are meant to give some recommendations for building an adequate part
support system.
Acceleration and deceleration of the part support system
The part support mechanism should be capable of fast movement and quick response: it should
be able to move with the maximum required speed during bending but it should also be capable
of changing speed quickly when a bending starts or stops.
When a large maximum part support speed is required, even so a large acceleration and
deceleration of the part support is needed to limit the maximum position error and overshoot.
The relation between maximum part support speed and required acceleration / deceleration is
quadratic. When the maximum speed becomes twice as large, the required acceleration becomes
four times as large to maintain the same maximum position error.
Hydraulic part support systems
1. Hose lines
Special care should be taken when using hose lines, because they react elastically on internal
over pressures. Hose lines can have the following disadvantages:
•
An increased maximum position error.
•
An increased amount of overshoot.
Hose lines should not be mounted between the flow control valve and the cylinder, but for
instance between the pressure control valve and the flow control valve.
2. Flow control valve
The maximum flow of the control valve should not be too large, but should be just large enough
to be able to reach the desired maximum part support speed.
To limit the maximum position error of the part support, it is better to select a flow control valve
which has a relatively short response time.
The flow control valve should be mounted as close as possible to the cylinder, to eliminate the
effect of hydraulic lines between the flow control valve and the cylinder.
Summary of Contents for DA-65
Page 1: ...Delem V0303 MACHINE PARAMETERS MANUAL DA 65 V7 DA 69 V7 DA 68PL V7 DA on Windows V1...
Page 17: ...Delem V1101 1 6...
Page 55: ...Delem V1101 3 16 Parameter 16 19 Not used...
Page 67: ...Delem V1101 3 28 Parameter 28 Not used...
Page 68: ...Delem V1101 3 29 Parameter 29 Not used...
Page 79: ...Delem V1101 3 40 Parameter 40 41 Not used...
Page 81: ...Delem V1101 3 43 Parameter 43 45 Not used...
Page 89: ...Delem V1101 3 53 Parameter 53 Not used...
Page 94: ...Delem V1101 3 58 Parameter 58 Not used...
Page 96: ...Delem V1101 3 60 Parameter 60 119 Not used...
Page 175: ...Delem V1101 6 5 6 4 Crowning parameters Figure 6 4 a...
Page 197: ...Delem V1101 8 3 8 3 Digital I axis parameters Figure 8 3 a...
Page 207: ...Delem V1101 9 5 Figure 9 2 c Figure 9 2 d...
Page 239: ......