
Delem
V0802, 3.131
Parameter 131:
UAP from floppy on/off 1/0
Range
: 0 - 1
Default
:
0
Units
:
-
Function
To read the UAP.CMD file from floppy.
Description
During development and testing it can be helpful to read the UAP.CMD file from floppy instead
of loading a complete new application.
0 = use the internal UAP file, if valid.
1 = load UAP.CMD from floppy
Press the key
to select the required setting.
With this parameter set to 1 the UAP.CMD file is read from floppy during start up.
The file UAP.CMD can be compared with the file APPL.CMD: it is a short text file with
instructions for the control to copy UAP files from floppy to the control. Make sure the intended
UAP (User Application) is present on the floppy disk.
After testing the UAP.CMD file you should set this parameter to 0 again. Once the UAP has
been tested and approved, the instructions of the UAP.CMD file can be integrated in the normal
application loading procedure. Therefore you should modify the APPL.CMD file on the
application floppy. Make sure the required UAP file is on the application disk with the other
files.
For more information about UAPs please contact Delem.
Summary of Contents for DA-65
Page 1: ...Delem V0303 MACHINE PARAMETERS MANUAL DA 65 V7 DA 69 V7 DA 68PL V7 DA on Windows V1...
Page 17: ...Delem V1101 1 6...
Page 55: ...Delem V1101 3 16 Parameter 16 19 Not used...
Page 67: ...Delem V1101 3 28 Parameter 28 Not used...
Page 68: ...Delem V1101 3 29 Parameter 29 Not used...
Page 79: ...Delem V1101 3 40 Parameter 40 41 Not used...
Page 81: ...Delem V1101 3 43 Parameter 43 45 Not used...
Page 89: ...Delem V1101 3 53 Parameter 53 Not used...
Page 94: ...Delem V1101 3 58 Parameter 58 Not used...
Page 96: ...Delem V1101 3 60 Parameter 60 119 Not used...
Page 175: ...Delem V1101 6 5 6 4 Crowning parameters Figure 6 4 a...
Page 197: ...Delem V1101 8 3 8 3 Digital I axis parameters Figure 8 3 a...
Page 207: ...Delem V1101 9 5 Figure 9 2 c Figure 9 2 d...
Page 239: ......