V1101, 5.32
Parameter 3:
Switch
Range
: 1 - 100
Default
:
3
Units
: mm
Function
Axis switching point from ‘ramp’ area to ‘gain’ area.
Description
For an accurate servo axis positioning three parameters are used: ‘Ramp’, ‘Switch’ and ‘Gain’.
When (actual position - programmed position) > Switch, the braking factor ‘Ramp’ is used,
otherwise ‘Gain’ is used.