AMT58x-CB CANopen®
10
4.6 RT Bus termination
WARNING
Power supply must be turned off before performing this operation!
A bus termination resistance is provided in the connection cap and
has to be activated as line termination in the last device of the
transmission line.
Use RT Switch to activate or deactivate the bus termination.
RT Description
1 = 2 = ON
Activated: if the encoder is the last device
in the transmission line
1 = 2 = OFF
Deactivated: if the encoder is not the last
device in the transmission line
4.7 Diagnostic LEDs
Two diagnostic LEDs located in the rear side of the connection cap
are designed to show the operating or fault status of the CANopen®
interface.
GREEN
LED
Description
ON
Encoder is in
Operational
state
Single flash
Encoder is in
Stopped
state
Blinking
Encoder is in
Pre-Operational
state
RED
LED
Description
ON
The CAN controller is switched off
Double flash
Node guarding error
Single flash
Max. number of warning errors
Blinking
Generic error or
Flash memory error
OFF No
error
During initialization, device carries out a hardware test to check LEDs
operation. Both LEDs light up.
Summary of Contents for AMT58 Series
Page 1: ......
Page 8: ......
Page 13: ...AMT58x CB CANopen 5 3 1 3 Fissaggio con flangia codice ST 58 FLNG ...
Page 52: ......
Page 55: ...Subject index ...
Page 62: ...AMT58x PB Profibus 5 3 1 3 Installation using a flange code ST 58 FLNG ...
Page 101: ......
Page 102: ......
Page 109: ......
Page 114: ...AMT58x EC EtherCAT 5 3 1 3 Installation using a flange code ST 58 FLNG ...
Page 166: ......
Page 167: ...AMT58 PN INSTRUCTION MANUAL Absolute Encoders ...
Page 180: ...LIST OF ABBREVIATIONS xiv AMT58 PN ...
Page 221: ...TO TECHNOLOGY OBJECTS INSTRUCTION MANUAL 41 Figure 28 TO encoder enabled ...
Page 231: ...INSTRUCTION MANUAL 51 ...
Page 265: ...NORMAL OPERATION DIAGRAM INSTRUCTION MANUAL 85 NORMAL OPERATION DIAGRAM ...
Page 266: ...ENCODER STATE MACHINE 86 AMT58 PN PRESET DIAGRAM ...
Page 267: ...PARKING SENSOR DIAGRAM INSTRUCTION MANUAL 87 PARKING SENSOR DIAGRAM ...
Page 269: ...ERROR DIAGRAM INSTRUCTION MANUAL 89 Acknowledgment of not acknowledgeable sensor error ...
Page 284: ......
Page 285: ......
Page 287: ......
Page 294: ......
Page 299: ...AMT58x CB CANopen 5 3 1 3 Installation using a flange code ST 58 FLNG ...
Page 335: ......
Page 345: ...AMT58x DN DeviceNET 5 3 1 3 Installation using a flange code ST 58 FLNG ...
Page 380: ...AMT58x DN DeviceNET 40 Default 21h ...
Page 384: ...AMT58x DN DeviceNET 44 Default 00h ...
Page 394: ......
Page 404: ...AMT58x PB Profibus 5 3 1 3 Installation using a flange code ST 58 FLNG ...