Wiring Diagrams for Reference
SiBE37-701_B
423
Appendix
FXSQ20P / 25P / 32P / 40P / 50P / 63P / 80P / 100P / 125P7VEB
1N~220-240V 50Hz
1N~220V 60Hz
L
N
Q1D1
L
N
X1M
GRN/YLW
Z1C
N=1
RED
BLU
A1P
Indoor
M1P
M
F1U
X27A
KPR
X25A
YLW YLW
Z2C
GRN
1~
PS
R1T
R2T R3T
X16A X18A X17A
X15A
t°
t°
t°
S1L
HAP
X35A
X70A
For 60~125 class (71~140 class)
A2P
To
X1M
RED
BLU X10A
F3U
X3A
X6A
R5T
K1R
HAP
V1R
L1R
X9A
C1
+
-
PS
R2
V2R
X1A
X2A
BLK
WHT
RED
YLW
BLU
ORG
PNK
GRY
M1F
MS
3~
5
BLK
BLK
A2P
RED
BLU
GRN X10A
F4U
HAP
Z1F
K1R
R1
X3A
For 20~50 class
(22~56 class)
L1R
X6A
F2U
RED
V1R
C1
PS
R2
X8A
WHT
BLU
ORG
BRN
M1F
MS
3~
M
Y1E
X7A
X28A
X33A
X38A
X30A
PNK
WHT
YLW
ORG
BLK
BLU
T2
T1
F2
F1
P2
P1
X2M
SS1
P2
P1
R1T
Wired remote control
(optional accessory)
Transmission wiring
Central remote control
note 2
Input from outside
note 3
L1R
Switch box (indoor)
A3P only for 60~125class (71~140 class)
A2P
Z
1
C
A
3
P
X1M X2M
A
1
P
X28A
X35A
X38A
X33A
2TW31186-1C
NOTES
1 Use copper conductors only.
2 When using the central remote control, see manual for connection to the unit.
3 When connecting the input wires from outside, forced off or on/off operation can be selected by the remote control.
See installation manual for more details.
: Field wiring
: Connector
: Wire clamp
: Protective earth screw
L:
Live
N:
Neutral
Colors:
RED:
Red
BLK:
Black
WHT:
White
YLW:
Yellow
ORG:
Orange
BRN:
Brown
GRY:
Gray
BLU:
Blue
PNK:
Pink
GRN:
Green
Indoor unit
PS
Switching power supply
Y1E
Electronic expansion valve
A1P
Printed circuit board
Q1DI
Earth leak detector
Z1C, Z2C Noise filter
A2P
Printed circuit board (fan)
R1
Resistor (current limiting)
Z1F
Noise filter
A3P
Printed circuit board (capacitor)
R2
Current sensing device
C1, C2, C3
Capacitor
R3, R4
Resistor (electric discharge)
F1UF
use (T, 3.15A, 250V)
R1T
Thermistor (suction air)
Connector optional accessory
F2UF
use (T, 5A, 250V)
R2T
Thermistor (Liquid)
X28A
Connector (power supply for wiring)
F3UF
use (T, 6.3A, 250V)
R3T
Thermistor (gas)
X35A
Connector (adapter)
F4UF
use (T, 6.3A, 250V)
R5T
Thermistor NTC (current limiting)
X38A
Connector (for wiring)
HAP
Light emitting diode (service monitor green)
S1L
Float switch
KPR, K1R Magnetic relay
V1R
Diode bridge
L1R
Reactor
V2R
Power module
Wired remote control
M1F
Motor (fan)
X1M
Terminal strip (power supply)
R1T
Thermistor (air)
M1P
Motor (drain pump)
X2M
Terminal strip (control)
SS1
Selector switch (main/sub)
C2
A3P
C3 R3 R4
+
-
+
-
Z2C
Summary of Contents for REYQ8-48PY1B
Page 1: ...Service Manual REYQ8 48PY1B R 410A Heat Recovery 50Hz SiBE37 701_B ...
Page 456: ...Piping Installation Point SiBE37 701_B 445 Appendix ...
Page 460: ...Example of connection SiBE37 701_B 449 Appendix ...
Page 476: ...Revision History Date News No Contents 2010 9 10 M 10011 Correction of service manual ...