Troubleshooting by Remote Controller
SiBE37-701_B
253
Troubleshooting
k
: ON
h
: OFF
l
: Blink
Malfunction
code
Operation
lamp
Malfunction contents
Page
Referred
Indoor Unit
A0
l
Error of external protection device
A1
l
PCB defect
A3
l
Malfunction of drain level control system (S1L)
A6
l
Fan motor (M1F) lock, overload
Malfunction of indoor unit fan motor
Overload/Overcurrent/Lock of indoor unit fan motor
A7
k
Malfunction of swing flap motor (M1S)
A8
l
Abnormal power supply voltage
A9
l
Electronic expansion valve malfunction / Dust clogging
Malfunction of electronic expansion valve coil
AF
k
Drain level above limit
AH
k
Malfunction of air filter maintenance
—
AJ
l
Malfunction of capacity determination device
C1
l
Failure of transmission (Between indoor unit PCB and fan PCB)
C4
l
Malfunction of thermistor (R2T) for heat exchanger
C5
l
Malfunction of thermistor (R3T) for gas pipes
C6
l
Failure of combination (Between indoor unit PCB and fan PCB)
C9
l
Malfunction of thermistor (R1T) for suction air
CJ
k
Malfunction of room temperature thermistor in remote controller
Outdoor Unit
E1
l
PCB defect
E3
l
Actuation of high pressure switch
E4
l
Actuation of low pressure sensor
E5
l
Inverter compressor motor lock
E6
l
STD compressor motor overcurrent/lock
E7
l
Malfunction of outdoor unit fan motor
E9
l
Malfunction of electronic expansion valve coil (Y1E ~ Y5E)
F3
l
Abnormal discharge pipe temperature
F6
l
Refrigerant overcharged
F9
l
Malfunction of BS unit electronic expansion valve
H7
l
Abnormal outdoor fan motor signal
H9
l
Malfunction of thermistor (R1T) for outdoor air
J2
l
Current sensor malfunction
J3
l
Malfunction of discharge pipe thermistor (R31T, R32T, R33T)
J4
l
Malfunction of temperature sensor for heat exchanger gas (R2T or R11T)
J5
l
Malfunction of thermistor (R8T or R10T) for suction pipe
J6
l
Malfunction of thermistor (R4T or R12T) for outdoor unit heat exchanger
J7
l
Malfunction of liquid pipe thermistor 1 (R6T, R9T or R14T)
J8
l
Malfunction of liquid pipe thermistor 2 (R7T or R15T)
J9
l
Malfunction of subcooling heat exchanger gas pipe thermistor (R5T or
R13T)
JA
l
Malfunction of high pressure sensor
JC
l
Malfunction of low pressure sensor
L1
l
Malfunction of inverter PCB
L4
l
Malfunction of inverter radiation fin temperature rise
L5
l
Momentary overcurrent of inverter compressor
L8
l
Momentary overcurrent of inverter compressor
L9
l
Inverter compressor starting failure
Summary of Contents for REYQ8-48PY1B
Page 1: ...Service Manual REYQ8 48PY1B R 410A Heat Recovery 50Hz SiBE37 701_B ...
Page 456: ...Piping Installation Point SiBE37 701_B 445 Appendix ...
Page 460: ...Example of connection SiBE37 701_B 449 Appendix ...
Page 476: ...Revision History Date News No Contents 2010 9 10 M 10011 Correction of service manual ...