SiBE37-701_B
Wiring Diagrams for Reference
Appendix
422
FXDQ20M / 25M9V3B
L
: LIVE
: CONNECTOR
: PROTECTIVE EARTH (SCREW)
: WIRE CLAMP
N
: NEUTRAL
FIELD WIRING
T1R
C1R
X2M
X1M
SWITCH BOX
A1P
SWITCH BOX COVER
1N~50Hz
230V
N
L
Q1E F2U
X1M
L N
RE
D
BL
U
R1T
R2T
R3T
indoor
T1R
A1P
X3A
X1A
X4A
C1R
WHT
YLW
L
N
F1
U
X13A
X12A
X11A X8A X16A
X18A
Ry
F1
Ry
F2
Ry
F3
FC FH
FL FLL
RED
BL
K
ORG
BRN
M1F
M
1~ t°
Y1E
M
X7A
HAP
T2
T1
F2
F1
P2
P1
PNK
WHT
YLW
ORG
BLU
BLK
T2
T1
F2
F1
P2
P1
X2M
X2A
F2U
X1A
F1U RyH Y2
Y1
YC
X4
X3
X2
X1
X1M
COMPRESSOR
OPERATION
FAN
OPERATION
TE
R
M
IN
A
LS
OPER
AT
IO
N
IN
DIC
A
TO
R
RyF
R
yC
AD
APT
OR
F
O
R
W
IR
IN
G
K1R
NOTE 3 INPUT
FROM OUTSIDE
CENTRAL REMOTE
CONTROLLER NOTE 1
WIRED
REMOTE
CONTROLLER
P1 P2
20, 25 CLASS
(22, 28 CLASS)
A1P
PRINTED CIRCUIT BOARD
RyF1-3
MAGNETIC RELAY (FAN)
ADAPTOR FOR WIRING
X1M
TERMINAL STRIP
C1R
CAPACITOR (FAN)
T1R
TRANSFORMER
(220-240V/22V)
RyC, RyF
MAGNETIC RELAY
CONNECTOR FOR OPTIONAL PARTS
F1U
FUSE (250V, 10A)
RyH
MAGNETIC RELAY (J1EH)
X16A
CONNECTOR (WIRING ADAPTOR)
F2U
FIELD FUSE
X1M
TERMINAL STRIP (POWER)
F1U, F2U
FUSE (250V, 5A)
X18A
CONNECTOR (WIRING ADAPTOR
FOR ELECTRICAL APPENDICES)
HAP
LIGHT EMITTING DIODE
(SERVICE MONITOR-GREEN)
X2M
TERMINAL STRIP (CONTROL)
X1A, X2A
CONNECTOR (WIRING ADAPTOR)
Y1E
ELECTRONIC EXPANSION
VALVE
M1F
MOTOR (FAN)
Q1E
EARTH LEAK DETECTOR
OPTIONAL PARTS
R1T
THERMISTOR (AIR)
J1EH
ELECTRIC HEATER
R2T, R3T
THERMISTOR (REFRIGERANT)
K1R
MAGNETIC RELAY (J1EH)
COLORS:
BLK : BLACK; BLU : BLUE; BRN : BROWN; ORG : ORANGE;
PNK : PINK; WHT : WHITE; YLW : YELLOW; RED : RED
NOTES:
1. USE COPPER CONDUCTORS ONLY.
2. WHEN USING THE CENTRAL REMOTE CONTROLLER, SEE MANUAL FOR CONNECTION TO THE UNIT.
3. WHEN INSTALLING THE ELECTRIC HEATER, CHANGE THE WIRING FOR THE HEATER CIRCUIT. THE MAIN POWER SUPPLY HAS TO BE SUPPLIED INDEPENDENTLY.
4. WHEN CONNECTING THE INPUT WIRES FROM OUTSIDE, “FORCED OFF” OR “ON/OFF” OPERATION CAN BE SELECTED BY THE REMOTE CONTROLLER.
SEE INSTALLATION MANUAL FOR DETAILS.
2TW23666-1E
t°
t°
t°
Summary of Contents for REYQ8-48PY1B
Page 1: ...Service Manual REYQ8 48PY1B R 410A Heat Recovery 50Hz SiBE37 701_B ...
Page 456: ...Piping Installation Point SiBE37 701_B 445 Appendix ...
Page 460: ...Example of connection SiBE37 701_B 449 Appendix ...
Page 476: ...Revision History Date News No Contents 2010 9 10 M 10011 Correction of service manual ...