![Daikin LRLEQ10AY1(E) Service Manual Download Page 8](http://html1.mh-extra.com/html/daikin/lrleq10ay1-e/lrleq10ay1-e_service-manual_502370008.webp)
SiENBE28-901
Standard Specification
Air Cooled Refrigeration Condensing Unit
7
2. Standard Specification
2.1
Standard Specification
Notes:
H
1 [ ] shows the anti-corrosion treatment type.
H
2 Rated conditions of the refrigeration equipment :
Saturated temperature equivalent to suction pressure: -10°C
Outdoor air: 32°C, Suction SH: 10°C
H
3 Measurement place: Front: 1m, Height: 1.5m
4 The minimum connection load with inside unit: 2.0kW
Model
1
LRMEQ5AY1
[LRMEQ5AY1E]
LRMEQ6AY1
[LRMEQ6AY1E]
Power Supply
3 phase 50Hz 380-415V
Capacity
2
kW
12.2
14.4
Range of Suction Pressure Equivalent
Saturation Temperature
°C
-20~+10
Range of Outdoor Temperature
°C
-15~+43
Casing Color
Ivory white (5Y7.5/1) [Light camel (2.5Y6.5/1.5)]
Dimensions: (H×W×D)
mm
1680×635×765
Heat Exchanger
Cross fin coil
Compressor
Type
Hermetically sealed scroll type
Piston Displacement
m
3
/h
10.04
13.85
Number of Revolutions
r.p.m
4740
6540
Motor Output × Number of Units
kW
2.3
3.2
Starting Method
Direct-on-line (Inverter system)
Fan
Type
Propeller fan
Motor Output
kW
0.35×1
Air Flow Rate
m
3
/min
95
102
Drive
Direct drive
Connecting
Pipes
Liquid Pipe
φ
9.5 C1220T (Brazing connection)
Gas Pipe
φ
19.1 C1220T (Brazing connection)
Receiver Volume
5.4
Mass
kg
175
Safety Devices
High Pressure Switch, Fan Driver Overload Protector, Overcurrent Relay,
Inverter Overload Protector, Fusible Plug
Capacity Control
%
33~100
24~100
Refrigerant
Refrigerant Name
R410A
Charge Volume
kg
5.2
Refrigerant
Oil
Refrigerant Oil Name
DAPHNE FVC68D
Charge Volume
L
1.7+2.5
Operating Sound
3
dBA
54
56
Standard Accessories
Installation Manual, Operation Manual, Connection Pipes, Clamps