Field Settings
SiENBE28-901
38
Air Cooled Refrigeration Condensing Unit
d. Setting method with the AIRNET or type-III checker.
1) In case of the AIRNET
• Use Setting Mode 2-6 (AIRNET address).
• Use Setting Mode 2-16 (virtual indoor unit address).
2) In case of a Type-III checker
• Use Setting Mode 2-16 (virtual indoor unit address).
No.
Display of setting items
Display of setting conditions
Setting item
H1P H2P H3P H4P H5P H6P H7P
6
AIRNET address
k h h h k k h
16
Virtual indoor unit address setting
k h k h h h h
• When there is 1 outdoor unit, set the
address to "1".
• When there are multiple outdoor units
(outdoor-outdoor transmission
connection), contact the After Sales
Service Division.
H1P H2P H3P H4P H5P H6P H7P Please give the
address of 1 or
more to when you
do the AIRNET.
Uses binary
numbers for the
address (six digits).
(Factory set) 0
k
h
h
h
h
h
h
1
k
h
h
h
h
h
k
~
63
k
k
k
k
k
k
k
H1P H2P H3P H4P H5P H6P H7P
(Factory set) 0
k
h
h
h
h
h
h
1
k
h
h
h
h
h
k
~
63
k
k
k
k
k
k
k