![background image](http://html.mh-extra.com/html/daikin/3mks50dvm/3mks50dvm_service-manual_501112037.webp)
Specifications
Si12-619A
24
Specifications
60Hz 220V
Model
FTKS60DVMT
FTKS71DVMT
Capacity
6.0kW Class
7.1kW Class
Front Panel Color
White
White
Air Flow Rates
m³/min
(cfm)
H
16.2 (572)
16.7 (590)
M
13.6 (480)
14.2 (501)
L
11.4 (402)
11.6 (409)
SL
10.2 (360)
10.6 (374)
Fan
Type
Cross Flow Fan
Cross Flow Fan
Motor Output
W
43
43
Speed
Steps
5 Steps, Quiet, Auto
5 Steps, Quiet, Auto
Air Direction Control
Right, Left, Horizontal, Downward
Right, Left, Horizontal, Downward
Air Filter
Removable-Washable-Mildew Proof
Removable-Washable-Mildew Proof
Running Current
A
0.21
0.23
Power Consumption
W
45
50
Power Factor
%
97.4
98.8
Temperature Control
Microcomputer Control
Microcomputer Control
Dimensions (H×W×D)
mm
290×1,050×238
290×1,050×238
Packaged Dimensions (H×W×D)
mm
337×1,147×366
337×1,147×366
Weight
kg
12
12
Gross Weight
kg
17
17
Operation
Sound
H/L/SL
dBA
45/41/36/33
46/42/37/34
Heat Insulation
Both Liquid and Gas Pipes
Both Liquid and Gas Pipes
Piping Connection
Liquid
mm
φ
6.4
φ
6.4
Gas
mm
φ
12.7
φ
15.9
Drain
mm
φ
18.0
φ
18.0
Drawing No.
3D049987
3D049988
Model
FTKS50FVLT
FTKS60FVLT
Capacity
5.0kW Class
6.0kW Class
Front Panel Color
White
White
Air Flow Rates
m³/min
(cfm)
H
14.7 (519)
16.2 (572)
M
12.4 (438)
13.6 (480)
L
10.3 (364)
11.4 (403)
SL
9.5 (335)
10.2 (360)
Fan
Type
Cross Flow Fan
Cross Flow Fan
Motor Output
W
43
43
Speed
Steps
5 Steps, Quiet, Auto
5 Steps, Quiet, Auto
Air Direction Control
Right, Left, Horizontal, Downward
Right, Left, Horizontal, Downward
Air Filter
Removable / Washable / Mildew Proof
Removable / Washable / Mildew Proof
Running Current
A
0.16
0.19
Power Consumption
W
34
40
Power Factor
%
96.6
95.7
Temperature Control
Microcomputer Control
Microcomputer Control
Dimensions (H×W×D)
mm
290×1,050×238
290×1,050×238
Packaged Dimensions (H×W×D)
mm
337×1,147×366
337×1,147×366
Weight
kg
12
12
Gross Weight
kg
17
17
Operation
Sound
H/M/L/SL
dBA
43/39/34/31
45/41/36/33
Heat Insulation
Both Liquid and Gas Pipes
Both Liquid and Gas Pipes
Piping Connection
Liquid
mm
φ
6.4
φ
6.4
Gas
mm
φ
12.7
φ
12.7
Drain
mm
φ
18.0
φ
18.0
Drawing No.
3D056228
3D056229
Conversion Formulae
kcal/h=kW×860
Btu/h=kW×3414
cfm=m³/min×35.3
Summary of Contents for 3MKS50DVM
Page 13: ...Introduction Si12 619A xii ...
Page 131: ...Control Specification Si12 619A 118 Function and Control ...
Page 213: ...Instruction Si12 619A 200 Operation Manual ...
Page 283: ...Check Si12 619A 270 Service Diagnosis ...
Page 302: ...Si12 619A Outdoor Unit E Series 50 52 58 Class Removal Procedure 289 Step Procedure Points ...
Page 385: ...Wiring Diagrams Si12 619A 372 Appendix FTK X S50 60 71FVLT ...
Page 399: ...Si12 619A vi Index ...