![background image](http://html.mh-extra.com/html/daikin/3mks50dvm/3mks50dvm_service-manual_501112031.webp)
Specifications
Si12-619A
18
Specifications
1. Specifications
1.1
Indoor Units - Cooling Only
Wall Mounted Type
50Hz 230V
Model
FTKS25DVM
FTKS35DVM
Rated Capacity
2.5kW Class
3.5kW Class
Front Panel Color
White
White
Air Flow Rates
m³/min
(cfm)
H
8.7 (307)
8.9 (314)
M
6.7 (237)
6.9 (242)
L
4.7 (166)
4.8 (169)
SL
3.9 (138)
4.0 (141)
Fan
Type
Cross Flow Fan
Cross Flow Fan
Motor Output
W
40
40
Speed
Steps
5 Steps, Quiet, Auto
5 Steps, Quiet, Auto
Air Direction Control
Right, Left, Horizontal, Downward
Right, Left, Horizontal, Downward
Air Filter
Removable-Washable-Mildew Proof
Removable-Washable-Mildew Proof
Running Current (Rated)
A
0.16
0.18
Power Consumption (Rated)
W
35
40
Power Factor
%
95.1
96.6
Temperature Control
Microcomputer Control
Microcomputer Control
Dimensions (H×W×D)
mm
283×800×195
283×800×195
Packaged Dimensions (H×W×D)
mm
265×855×340
265×855×340
Weight
kg
9
9
Gross Weight
kg
12
12
Operation
Sound
H/L/SL
dBA
37/25/22
39/26/23
Heat Insulation
Both Liquid and Gas Pipes
Both Liquid and Gas Pipes
Piping Connection
Liquid
mm
φ
6.4
φ
6.4
Gas
mm
φ
9.5
φ
9.5
Drain
mm
φ
18.0
φ
18.0
Drawing No.
3D049321
3D049322
Model
FTKS50BVMB
FTKS60BVMB
Rated Capacity
5.0kW Class
6.0kW Class
Front Panel Color
White
White
Air Flow Rates
m³/min
(cfm)
H
11.4 (402)
16.2 (572)
M
9.7 (342)
13.6 (480)
L
8.0 (282)
11.4 (402)
SL
7.1 (251)
10.2 (360)
Fan
Type
Cross Flow Fan
Cross Flow Fan
Motor Output
W
40
43
Speed
Steps
5 Steps, Quiet, Auto
5 Steps, Quiet, Auto
Air Direction Control
Right, Left, Horizontal, Downward
Right, Left, Horizontal, Downward
Air Filter
Removable-Washable-Mildew Proof
Removable-Washable-Mildew Proof
Running Current (Rated)
A
0.18
0.18
Power Consumption (Rated)
W
40
40
Power Factor
%
96.6
96.6
Temperature Control
Microcomputer Control
Microcomputer Control
Dimensions (H×W×D)
mm
290×795×238
290×1,050×238
Packaged Dimensions (H×W×D)
mm
280×840×338
337×1,147×366
Weight
kg
9
12
Gross Weight
kg
13
17
Operation
Sound
H/M/L/SL
dBA
44/40/35/32
45/41/36/33
Sound Power
H
dBA
63
63
Heat Insulation
Both Liquid and Gas Pipes
Both Liquid and Gas Pipes
Piping Connection
Liquid
mm
φ
6.4
φ
6.4
Gas
mm
φ
12.7
φ
12.7
Drain
mm
φ
18.0
φ
18.0
Drawing No.
3D040781A
3D040782A
Conversion Formulae
kcal/h=kW×860
Btu/h=kW×3414
cfm=m³/min×35.3
Summary of Contents for 3MKS50DVM
Page 13: ...Introduction Si12 619A xii ...
Page 131: ...Control Specification Si12 619A 118 Function and Control ...
Page 213: ...Instruction Si12 619A 200 Operation Manual ...
Page 283: ...Check Si12 619A 270 Service Diagnosis ...
Page 302: ...Si12 619A Outdoor Unit E Series 50 52 58 Class Removal Procedure 289 Step Procedure Points ...
Page 385: ...Wiring Diagrams Si12 619A 372 Appendix FTK X S50 60 71FVLT ...