![background image](http://html.mh-extra.com/html/daikin/3mks50dvm/3mks50dvm_service-manual_501112326.webp)
Si12-619A
Outdoor Unit – E Series (68 / 71 / 75 Class), D Series
Removal Procedure
313
2.6
Removal of the
Four Way Valve Coil
,
Solenoid Valve
Coil
,
Electronic Expansion Valve Coil
and
Thermistor
Procedure
Warning
Be sure to wait 10 minutes or more after turning off all power supplies
before disassembling work.
Step
Procedure
Points
1
Remove the screw of
the four way valve coil.
2
Remove the screw of
the solenoid valve coil.
3
Remove the electronic
expansion valve coil for
each room.
Place the thermistor so that
its end comes up to the end
of the presser spring.
4
Release the thermistor
presser spring, and
remove the discharge
pipe thermistor.
Be careful not to lose the
presser spring for the
discharge pipe thermistor.