![background image](http://html.mh-extra.com/html/daikin/3mks50dvm/3mks50dvm_service-manual_501112035.webp)
Specifications
Si12-619A
22
Specifications
50Hz 220-230-240V / 60Hz 220-230V
60Hz 220V
Model
FTKS71FVMA
Rated Capacity
7.1kW Class
Front Panel Color
White
Air Flow Rates
m³/min
(cfm)
H
17.4 (614)
M
14.6 (516)
L
11.9 (420)
SL
11.2 (395)
Fan
Type
Cross Flow Fan
Motor Output
W
43
Speed
Steps
5 Steps, Quiet, Auto
Air Direction Control
Right, Left, Horizontal, Downward
Air Filter
Removable-Washable-Mildew Proof
Running Current (Rated)
A
0.21-0.20-0.19/0.21-0.20
Power Consumption (Rated)
W
45
Power Factor
%
97.4-97.8-98.7/97.4-97.8
Temperature Control
Microcomputer Control
Dimensions (H×W×D)
mm
290×1,050×238
Packaged Dimensions (H×W×D)
mm
337×1,147×366
Weight
kg
12
Gross Weight
kg
17
Operation
Sound
H/M/L/SL
dBA
46/42/37/34
Sound Power
H
dBA
62
Heat Insulation
Both Liquid and Gas Pipes
Piping Connection
Liquid
mm
φ
6.4
Gas
mm
φ
15.9
Drain
mm
φ
18.0
Drawing No.
3D054878A
Model
FTKS20DVMT
FTKS25DVMT
Capacity
2.0kW Class
2.5kW Class
Front Panel Color
White
White
Air Flow Rates
m³/min
(cfm)
H
8.7 (307)
8.7 (307)
M
6.7 (237)
6.7 (237)
L
4.7 (166)
4.7 (166)
SL
3.9 (138)
3.9 (138)
Fan
Type
Cross Flow Fan
Cross Flow Fan
Motor Output
W
40
40
Speed
Steps
5 Steps, Quiet, Auto
5 Steps, Quiet, Auto
Air Direction Control
Right, Left, Horizontal, Downward
Right, Left, Horizontal, Downward
Air Filter
Removable-Washable-Mildew Proof
Removable-Washable-Mildew Proof
Running Current
A
0.17
0.17
Power Consumption
W
35
35
Power Factor
%
93.6
93.6
Temperature Control
Microcomputer Control
Microcomputer Control
Dimensions (H×W×D)
mm
283×800×195
283×800×195
Packaged Dimensions (H×W×D)
mm
265×855×340
265×855×340
Weight
kg
9
9
Gross Weight
kg
12
12
Operation
Sound
H/L/SL
dBA
38/25/22
38/25/22
Heat Insulation
Both Liquid and Gas Pipes
Both Liquid and Gas Pipes
Piping Connection
Liquid
mm
φ
6.4
φ
6.4
Gas
mm
φ
9.5
φ
9.5
Drain
mm
φ
18.0
φ
18.0
Drawing No.
3D049894A
3D049895A
Conversion Formulae
kcal/h=kW×860
Btu/h=kW×3414
cfm=m³/min×35.3
Summary of Contents for 3MKS50DVM
Page 13: ...Introduction Si12 619A xii ...
Page 131: ...Control Specification Si12 619A 118 Function and Control ...
Page 213: ...Instruction Si12 619A 200 Operation Manual ...
Page 283: ...Check Si12 619A 270 Service Diagnosis ...
Page 302: ...Si12 619A Outdoor Unit E Series 50 52 58 Class Removal Procedure 289 Step Procedure Points ...
Page 385: ...Wiring Diagrams Si12 619A 372 Appendix FTK X S50 60 71FVLT ...
Page 399: ...Si12 619A vi Index ...