![background image](http://html.mh-extra.com/html/daikin/3mks50dvm/3mks50dvm_service-manual_501112058.webp)
Si12-619A
Specifications
Specifications
45
Floor / Ceiling Suspended Dual Type
50Hz 230V
50Hz 220-230-240V / 60Hz 220-230V
Model
FLXS25BVMA
FLXS35BVMA
Cooling
Heating
Cooling
Heating
Rated Capacity
2.5kW Class
3.5kW Class
Front Panel Color
Almond White
Almond White
Air Flow Rates
m³/min
(cfm)
H
7.6 (268)
9.2 (325)
8.6 (304)
9.8 (346)
M
6.8 (240)
8.3 (293)
7.6 (268)
8.9 (314)
L
6.0 (212)
7.4 (261)
6.6 (233)
8.0 (282)
SL
5.2 (184)
6.6 (233)
5.6 (198)
7.2 (254)
Fan
Type
Sirocco Fan
Sirocco Fan
Motor Output
W
34
34
Speed
Steps
5 Steps, Quiet, Auto
5 Steps, Quiet, Auto
Air Direction Control
Right, Left, Horizontal, Downward
Right, Left, Horizontal, Downward
Air Filter
Removable-Washable-Mildew Proof
Removable-Washable-Mildew Proof
Running Current (Rated)
A
0.32
0.34
0.36
0.36
Power Consumption (Rated)
W
70
74
78
78
Power Factor
%
95.1
94.6
94.2
94.2
Temperature Control
Microcomputer Control
Microcomputer Control
Dimensions (H×W×D)
mm
490×1,050×200
490×1,050×200
Packaged Dimensions (H×W×D)
mm
280×1,100×566
280×1,100×566
Weight
kg
16
16
Gross Weight
kg
22
22
Operation
Sound
H/M/L/SL
dBA
37/34/31/28
37/34/31/29
38/35/32/29
39/36/33/30
Heat Insulation
Both Liquid and Gas Pipes
Both Liquid and Gas Pipes
Piping Connection
Liquid
mm
φ
6.4
φ
6.4
Gas
mm
φ
9.5
φ
9.5
Drain
mm
φ
18.0
φ
18.0
Drawing No.
3D046600
3D046601
Model
FLXS50BVMA
FLXS60BVMA
Cooling
Heating
Cooling
Heating
Rated Capacity
5.0kW Class
5.7kW Class
Front Panel Color
Almond White
Almond White
Air Flow Rates
m³/min
(cfm)
H
11.4 (403)
12.1 (427)
12.0 (424)
12.8 (452)
M
10.0 (353)
9.8 (346)
10.7 (378)
10.6 (374)
L
8.5 (300)
7.5 (265)
9.3 (328)
8.4 (297)
SL
7.5 (265)
6.8 (240)
8.3 (293)
7.5 (265)
Fan
Type
Sirocco Fan
Sirocco Fan
Motor Output
W
34
34
Speed
Steps
5 Steps, Quiet, Auto
5 Steps, Quiet, Auto
Air Direction Control
Right, Left, Horizontal, Downward
Right, Left, Horizontal, Downward
Air Filter
Removable-Washable-Mildew Proof
Removable-Washable-Mildew Proof
Running Current (Rated)
A
0.47-0.45-0.43/0.47-0.45
0.47-0.45-0.43/0.47-0.45
0.49-0.47-0.45/0.49-0.47
0.47-0.45-0.43/0.47-0.45
Power Consumption (Rated)
W
96
96
98
96
Power Factor
%
92.8-92.8-93.0/92.8-92.8
92.8-92.8-93.0/92.8-92.8
90.9-90.7-90.7/90.9-90.7
92.8-92.8-93.0/92.8-92.8
Temperature Control
Microcomputer Control
Microcomputer Control
Dimensions (H×W×D)
mm
490×1,050×200
490×1,050×200
Packaged Dimensions (H×W×D)
mm
280×1,100×566
280×1,100×566
Weight
kg
17
17
Gross Weight
kg
24
24
Operation
Sound
H/M/L/SL
dBA
47/43/39/36
46/41/35/33
48/45/41/39
47/42/37/34
Sound Power
H
dBA
63
62
64
63
Heat Insulation
Both Liquid and Gas Pipes
Both Liquid and Gas Pipes
Piping Connection
Liquid
mm
φ
6.4
φ
6.4
Gas
mm
φ
12.7
φ
12.7
Drain
mm
φ
18.0
φ
18.0
Drawing No.
3D055049
3D055050
Conversion Formulae
kcal/h=kW×860
Btu/h=kW×3414
cfm=m³/min×35.3
Summary of Contents for 3MKS50DVM
Page 13: ...Introduction Si12 619A xii ...
Page 131: ...Control Specification Si12 619A 118 Function and Control ...
Page 213: ...Instruction Si12 619A 200 Operation Manual ...
Page 283: ...Check Si12 619A 270 Service Diagnosis ...
Page 302: ...Si12 619A Outdoor Unit E Series 50 52 58 Class Removal Procedure 289 Step Procedure Points ...
Page 385: ...Wiring Diagrams Si12 619A 372 Appendix FTK X S50 60 71FVLT ...
Page 399: ...Si12 619A vi Index ...