Si12-619A
Piping Diagrams
Appendix
365
4MKS90EVMA, 4MKS100EVLT, 4MKS80ESG
3MKS90EVLT
3D051940
REFRIGERANT FLOW
HEADER
12.7CuT
12.7CuT
OUTDOOR UNIT
COOLING
7.9CuT
7.9CuT
7.9CuT
7.9CuT
7.9CuT
7.9CuT
7.9CuT
7.9CuT
PROPELLER FAN
DC FAN MOTOR
DISCHARGE PIPE
THERMISTOR
COMPRESSOR
HEAT EXCHANGER
7.9CuT
M
7.9CuT
HEAT EXCHANGER
(CONDENSER)
THERMISTOR
ACCUMULATOR
7.9CuT
OUTDOOR TEMPERATURE
THERMISTOR
CAPILLARY TUBE
15.9CuT
DISTRIBUTOR
9.5CuT
ACCUMULATOR
9.5CuT
15.9CuT
15.9CuT
LIQUID LINE
STOP VALVE
GAS LINE
STOP VALVE
9.5CuT
15.9CuT
HEADER
HEADER
FILTER
7.9CuT
7.9CuT
7.9CuT
7.9CuT
12.7CuT
12.7CuT
12.7CuT
12.7CuT
MOTOR OPERATED
VALVE (D)
MOTOR OPERATED
VALVE (C)
MOTOR OPERATED
VALVE (B)
MOTOR OPERATED
VALVE (A)
EV
A
EV
C
EV
B
EV
D
GAS PIPE THERMISTOR
(ROOM-D)
GAS PIPE THERMISTOR
(ROOM-C)
GAS PIPE THERMISTOR
(ROOM-B)
GAS PIPE THERMISTOR
(ROOM-A)
LIQUID PIPE
THERMISTOR
(ROOM-D)
LIQUID PIPE
THERMISTOR
(ROOM-C)
LIQUID PIPE
THERMISTOR
(ROOM-B)
LIQUID PIPE
THERMISTOR
(ROOM-A)
FILTER
FILTER
FILTER
FILTER
ROOM B
(6.4 CuT)
ROOM C
(15.9 CuT)
ROOM C
(6.4 CuT)
ROOM D
(6.4 CuT)
ROOM A
(9.5 CuT)
ROOM B
(12.7 CuT)
ROOM D
(15.9 CuT)
ROOM A
(6.4 CuT)
FIELD
PIPING
LIQUID
FIELD
PIPING
GAS
REFRIGERANT FLOW
HEADER
12.7CuT
12.7CuT
OUTDOOR UNIT
COOLING
7.9CuT
7.9CuT
7.9CuT
7.9CuT
7.9CuT
7.9CuT
7.9CuT
7.9CuT
PROPELLER FAN
DC FAN MOTOR
DISCHARGE PIPE
THERMISTOR
COMPRESSOR
HEAT EXCHANGER
7.9CuT
M
7.9CuT
HEAT EXCHANGER
(CONDENSER)
THERMISTOR
ACCUMULATOR
7.9CuT
OUTDOOR TEMPERATURE
THERMISTOR
CAPILLARY TUBE
15.9CuT
DISTRIBUTOR
9.5CuT
ACCUMULATOR
9.5CuT
15.9CuT
15.9CuT
LIQUID LINE
STOP VALVE
GAS LINE
STOP VALVE
9.5CuT
15.9CuT
HEADER
HEADER
FILTER
7.9CuT
7.9CuT
7.9CuT
12.7CuT
12.7CuT
12.7CuT
MOTOR OPERATED
VALVE (C)
MOTOR OPERATED
VALVE (B)
MOTOR OPERATED
VALVE (A)
EV
A
EV
B
EV
C
GAS PIPE THERMISTOR
(ROOM-C)
GAS PIPE THERMISTOR
(ROOM-B)
GAS PIPE THERMISTOR
(ROOM-A)
LIQUID PIPE
THERMISTOR
(ROOM-C)
LIQUID PIPE
THERMISTOR
(ROOM-B)
LIQUID PIPE
THERMISTOR
(ROOM-A)
FILTER
FILTER
FILTER
ROOM C
(15.9 CuT)
ROOM A
(9.5 CuT)
ROOM C
(6.4 CuT)
ROOM B
(12.7 CuT)
ROOM A
(6.4 CuT)
ROOM B
(6.4 CuT)
FIELD
PIPING
GAS
FIELD
PIPING
LIQUID
3D051942
Summary of Contents for 3MKS50DVM
Page 13: ...Introduction Si12 619A xii ...
Page 131: ...Control Specification Si12 619A 118 Function and Control ...
Page 213: ...Instruction Si12 619A 200 Operation Manual ...
Page 283: ...Check Si12 619A 270 Service Diagnosis ...
Page 302: ...Si12 619A Outdoor Unit E Series 50 52 58 Class Removal Procedure 289 Step Procedure Points ...
Page 385: ...Wiring Diagrams Si12 619A 372 Appendix FTK X S50 60 71FVLT ...
Page 399: ...Si12 619A vi Index ...