![background image](http://html.mh-extra.com/html/daikin/3mks50dvm/3mks50dvm_service-manual_501112303.webp)
Outdoor Unit – E Series (50 / 52 / 58 Class)
Si12-619A
290
Removal Procedure
1.4
Removal of the Propeller Fan / Fan Motor
Procedure
Warning
Be sure to wait 10 minutes or more after turning off all power supplies
before disassembling work.
Step
Procedure
Points
1
Remove the fan motor
fixing plate.
Remove the outer panels
and plates.
Remove the electrical box.
2
Take out the fan motor
fixing plate toward
yourself.
When assembling, fit the
lower hooks.
3
Loosen the washer
fitted nut to remove the
propeller fan.
When assembling, align
mark of the propeller fan with
D-cut section of the motor
shaft.
When assembling, make
sure
z
mark of the fan motor
goes up.