![background image](http://html.mh-extra.com/html/daikin/2mxu40gv1b/2mxu40gv1b_service-manual_501101259.webp)
SiBE12-908
Outdoor Unit
Removal Procedure
248
2.12 Removal of Thermistors
Procedure
Warning
Be sure to wait 10 minutes or more after turning off all power supplies
before disassembling work.
Step
Procedure
Points
1. Removal of the assembly
of thermistor
Be careful not to lose the clip
for the discharge pipe
thermistor.
1
Undo the clip and
remove the discharge
pipe thermistor.
2
Cut off the clamp to pull
out the heat exchanger
thermistor.
The clamp is always
reserved.
Be careful not to lose the
clips for each thermistor.
3
The outdoor air /
discharge pipe / heat
exchanger thermistors
are united as one
assembly.
4
The figure shows the
arrangement of the
assembly of thermistor
[S90].
2. Removal of the liquid /
gas pipe thermistors
1
Remove the liquid / gas
pipe thermistors.
(R9984)
Discharge pipe thermistor
(R7702)
(R7631)
Heat exchanger
thermistor
(R9985)
Outdoor air thermistor
(R9986)