SiBE12-908
Piping Diagrams
Appendix
260
1.2
Outdoor Units
2MXU40GV1B
2MXU50GV1B
}
}
3D063308
OUTDOOR UNIT
BRANCH
PIPE
7.0CuT
7.0CuT
HEAT EXCHANGER
OUTDOOR TEMPERATURE
THERMISTOR
6.4CuT
MUFFLER
WITH
BRANCH
4.8CuT
4.8CuT
HEAT EXCHANGER
THERMISTOR
FAN MOTOR
9.5CuT
PROPELLER FAN
M
9.5CuT
FOUR WAY VALVE
ON:HEATING
9.5CuT
7.9CuT
MUFFLER
7.9CuT
9.5CuT
BRANCH
PIPE
ACCUMULATOR
COMPRESSOR
DISCHARGE PIPE
THERMISTOR
REFRIGERANT FLOW
COOLING
BRANCH
PIPE
6.4CuT
6.4CuT
6.4CuT
6.4CuT
6.4CuT
MOTOR OPERATED VALVE
MUFFLER
WITH
FILTER
MUFFLER
LIQUID PIPE
THERMISTOR
LIQUID LINE
STOP VALVE
EV
A
MOTOR OPERATED VALVE MUFFLER
WITH
FILTER MUFFLER
LIQUID PIPE
THERMISTOR
LIQUID LINE
STOP VALVE
EV
B
ROOM A
(6.4 CuT)
ROOM B
(6.4 CuT)
FIELD
PIPING
LIQUID
ROOM A
(9.5 CuT)
ROOM B
(9.5 CuT)
FIELD
PIPING
GAS
MUFFLER BRANCH
PIPE
9.5CuT
9.5CuT
9.5CuT
9.5CuT
9.5CuT
MUFFLER
GAS PIPE
THERMISTOR
GAS LINE
STOP VALVE
GAS LINE
STOP VALVE
GAS PIPE
THERMISTOR
MUFFLER
HEATING
}
}
3D063309
OUTDOOR UNIT
BRANCH
PIPE
7.9CuT
7.9CuT
HEAT EXCHANGER
OUTDOOR TEMPERATURE
THERMISTOR
6.4CuT
MUFFLER
WITH
BRANCH
4.8CuT
4.8CuT
HEAT EXCHANGER
THERMISTOR
FAN MOTOR
9.5CuT
PROPELLER FAN
M
9.5CuT
FOUR WAY VALVE
ON:HEATING
9.5CuT
7.9CuT
MUFFLER
7.9CuT
9.5CuT
ACCUMULATOR
COMPRESSOR
DISCHARGE PIPE
THERMISTOR
REFRIGERANT FLOW
COOLING
BRANCH
PIPE
6.4CuT
6.4CuT
6.4CuT
MOTOR OPERATED VALVE
FILTER
LIQUID PIPE
THERMISTOR
LIQUID LINE
STOP VALVE
EV
A
MOTOR OPERATED VALVE
LIQUID LINE
STOP VALVE
EV
B
ROOM A
(6.4 CuT)
ROOM B
(6.4 CuT)
FIELD
PIPING
LIQUID
ROOM A
(9.5 CuT)
ROOM B
(12.7 CuT)
FIELD
PIPING
GAS
BRANCH
PIPE
9.5CuT
9.5CuT
9.5CuT
9.5CuT
9.5CuT
MUFFLER
GAS PIPE
THERMISTOR
GAS LINE
STOP VALVE
GAS LINE
STOP VALVE
GAS PIPE
THERMISTOR
MUFFLER
HEATING
FILTER
6.4CuT
LIQUID PIPE
THERMISTOR