![background image](http://html.mh-extra.com/html/daikin/2mxu40gv1b/2mxu40gv1b_service-manual_501101016.webp)
Specifications
SiBE12-908
5
Specifications
1. Specifications
1.1
Indoor Units
50Hz 220-230-240V
Note:
1.
★
: In humidifying operation, the operation sound increases by about 2dB in the indoor unit.
2. The humidifying capacity is 450ml/h under the following condition.
Outdoor air temperature: 7°CDB / 6°CWB
Humidifying hose length: 4.0m
Airflow rate of indoor unit: H tap
Model
CTXU25G2V1B
CTXU35G2V1B
Cooling
Heating
Cooling
Heating
Rated Capacity
2.5kW Class
3.5kW Class
Front Panel Color
White
White
Airflow Rate
m³/min
(cfm)
H
9.1 (321)
9.8 (346)
10.4 (367)
10.6 (374)
M
7.1 (252)
7.9 (280)
7.7 (270)
8.5 (302)
L
5.2 (182)
6.2 (217)
4.8 (170)
6.4 (226)
SL
3.7 (130)
5.2 (183)
3.5 (125)
5.4 (191)
Fan
Type
Cross Flow Fan
Cross Flow Fan
Motor Output
W
23
23
Speed
Steps
5 Steps, Quiet, Auto
5 Steps, Quiet, Auto
Air Direction Control
Right, Left, Horizontal, Downward
Right, Left, Horizontal, Downward
Air Filter
Removable / Washable / Mildew Proof
Removable / Washable / Mildew Proof
Running Current (Rated)
A
0.09-0.08-0.08
0.10-0.10-0.09
0.12-0.12-0.11
0.13-0.13-0.12
Power Consumption (Rated)
W
18
21
26
28
Power Factor
%
90.9-97.8-93.8
95.5-91.3-97.2
98.5-94.2-98.5
97.9-93.6-97.2
Temperature Control
Microcomputer Control
Microcomputer Control
Dimensions (H×W×D)
mm
295×800×215
295×800×215
Packaged Dimensions (H×W×D)
mm
274×870×366
274×870×366
Weight
kg
9
10
Gross Weight
kg
13
14
Operation
Sound
★
H/M/L/SL
dBA
38/32/25/22
39/34/28/25
42/34/26/23
42/36/29/26
Sound Power
H
dBA
54
55
58
58
Heat Insulation
Both Liquid and Gas Pipes
Both Liquid and Gas Pipes
Piping Connection
Liquid
mm
φ
6.4
φ
6.4
Gas
mm
φ
9.5
φ
9.5
Drain
mm
φ
18.0
φ
18.0
Drawing No.
3D063377
3D063378
Model
CTXU42G2V1B
CTXU50G2V1B
Cooling
Heating
Cooling
Heating
Rated Capacity
4.2kW Class
5.0kW Class
Front Panel Color
White
White
Airflow Rate
m³/min
(cfm)
H
9.1 (321)
11.2 (395)
10.2 (360)
11.0 (388)
M
7.7 (273)
9.4 (333)
8.6 (305)
9.3 (330)
L
6.3 (221)
7.7 (271)
7.0 (246)
7.6 (267)
SL
5.4 (190)
6.8 (240)
6.0 (212)
6.7 (236)
Fan
Type
Cross Flow Fan
Cross Flow Fan
Motor Output
W
23
23
Speed
Steps
5 Steps, Quiet, Auto
5 Steps, Quiet, Auto
Air Direction Control
Right, Left, Horizontal, Downward
Right, Left, Horizontal, Downward
Air Filter
Removable / Washable / Mildew Proof
Removable / Washable / Mildew Proof
Running Current (Rated)
A
0.11-0.11-0.10
0.14-0.14-0.13
0.12-0.12-0.11
0.15-0.14-0.14
Power Consumption (Rated)
W
24
30
26
32
Power Factor
%
99.2-94.9-100.0
97.4-93.2-96.2
98.5-94.2-98.5
97.0-99.4-95.2
Temperature Control
Microcomputer Control
Microcomputer Control
Dimensions (H×W×D)
mm
295×800×215
295×800×215
Packaged Dimensions (H×W×D)
mm
274×870×366
274×870×366
Weight
kg
10
10
Gross Weight
kg
14
14
Operation
Sound
★
H/M/L/SL
dBA
42/38/33/30
42/38/33/30
43/39/34/31
44/39/34/31
Sound Power
H
dBA
58
58
59
60
Heat Insulation
Both Liquid and Gas Pipes
Both Liquid and Gas Pipes
Piping Connection
Liquid
mm
φ
6.4
φ
6.4
Gas
mm
φ
9.5
φ
12.7
Drain
mm
φ
18.0
φ
18.0
Drawing No.
3D063379
3D063380
Conversion Formulae
kcal/h=kW×860
Btu/h=kW×3414
cfm=m³/min×35.3