Specifications
SiBE12-908
7
Specifications
50Hz 220-230-240V
Note:
1. The data are based on the conditions shown in the table below.
2.
★
: In humidifying operation, the operation sound increases by about 3dB in the outdoor unit.
Model
2MXU50GV1B
Cooling
Heating
Capacity
kW
—
Power Consumption
W
—
Running Current
A
—
Casing Color
Ivory White
Compressor
Type
Hermetically Sealed Swing Type
Model
2YC36BXD
Motor Output
W
1,100
Refrigerant Oil
Model
FVC50K
Charge
L
0.65
Refrigerant
Type
R-410A
Charge
kg
1.60
Airflow Rate
m³/min
HH
37
34
H
34
34
L
34
34
cfm
HH
1,306
1,200
H
1,200
1,200
L
1,200
1,200
Fan
Type
Propeller
Motor Output
W
50
Starting Current
A
6.3
Dimensions (H×W×D)
mm
675×765×285
Packaged Dimensions (H×W×D)
mm
739×907×390
Weight
kg
49
Gross Weight
kg
54
Operation Sound
★
dBA
48
50
Sound Power
dBA
63
—
Piping Connection
Liquid
mm
φ
6.4×2
Gas
mm
φ
9.5×1,
φ
12.7×1
Drain
mm
φ
18.0
Heat Insulation
Both Liquid and Gas Pipes
No. of Wiring Connection
3 for Power Supply, 4 for Interunit Wiring
Max. Interunit Piping Length
m
30 (for Total of Each Room)
m
15 (for One Room)
Min. Interunit Piping Length
m
3 (for One Room)
Amount of Additional Charge
g/m
20 (20m or more)
Max. Installation Height Difference
m
15 (between Indoor Unit and Outdoor Unit)
m
7.5 (between Indoor Units)
Drawing No.
3D063330A
Conversion Formulae
kcal/h=kW×860
Btu/h=kW×3414
cfm=m³/min×35.3
Cooling
Heating
Piping Length
Indoor ; 27°CDB/19°CWB
Outdoor ; 35°CDB
Indoor ; 20°CDB
Outdoor ; 7°CDB/6°CWB
5m