![background image](http://html.mh-extra.com/html/daikin/2mxu40gv1b/2mxu40gv1b_service-manual_501101258.webp)
Outdoor Unit
SiBE12-908
247
Removal Procedure
5
Turn the fan motor
fixing plate backward
and undo the 2 fixing
hooks of the lead wire.
6
Release the fan motor
lead wire.
When reassembling, put the
lead wire through the back of
the motor (so as not to be
entangled with the propeller
fan).
7
Remove the 4 screws
and 4 rubber vibration
isolators to remove the
fun motor.
Step
Procedure
Points
(R9983)
(R7627)
(R3249)
Lead wire
Propeller fan
(R7628)
(R7629)