1.13.5 ON/OFF Button on Indoor Unit
An ON/OFF button is provided on the front panel of the unit. Use this button when the remote
controller is missing or if its battery has run out.
Every press of the button switches from ON to OFF or from OFF to ON.
Push this button once to start operation. Push once again to stop it.
This button is useful when the remote controller is missing.
The operation mode refers to the following table.
In the case of multi system operation, there are times when the unit does not activate with
this button.
<Forced operation mode>
Forced operation mode can be set by pressing the ON/OFF button on the indoor unit for 5 to 9
seconds while the unit is not operating.
See page 53 for the detail of "Forced Operation Mode".
Note:
When the ON/OFF button on the indoor unit is pressed for 10 seconds or more, the forced
operation is stopped.
1.13.6 Titanium Apatite Photocatalytic Air-Purifying Filter
This filter combines the Air Purifying Filter and Titanium Apatite Photocatalytic Deodorizing
Filter in a single highly effective unit. The filter traps microscopic particles, decompose odors
and even deactivates bacteria and viruses. It lasts for 3 years without replacement if washed
about once every 6 months.
1.13.7 Air Filter (Prefilter)
The air filter net is impregnated with a safe, odorless mold preventative to make the filter
virtually immune to mold.
1.13.8 Auto-restart Function
Even if a power failure (including one for just a moment) occurs during the operation, the
operation restarts in the condition before power failure automatically when power is restored.
(Note) It takes 3 minutes to restart the operation because the 3-minute standby function is
activated.
ON / OFF
(R9408)
ON/OFF button
Mode
Temperature setting
Airflow rate
Heat Pump
AUTO
25
°
C
AUTO