Outdoor Unit
SiBE12-908
245
Removal Procedure
2.11 Removal of the Propeller Fan / Fan Motor
Procedure
Warning
Be sure to wait 10 minutes or more after turning off all power supplies
before disassembling work.
Step
Procedure
Points
1. Removal of the propeller
fan
Spanner size: 10mm
1
Unscrew the washer
fitted nut (M6) by an
open-ended spanner to
remove the propeller
fan.
When reassembling, align
mark of the propeller fan
with D-cut section of the
motor shaft.
2. Removal of the fan motor
1
Disconnect the
connector [S70] for the
fan motor from the
PCB.
(R9977)
Propeller fan
(R9978)
(R7620)
(R9979)
[S70]