SiBE12-908
Outdoor Unit
Removal Procedure
232
3
Release the mounting
plate from the hook.
When reassembling, make
sure to hook the mounting
plate.
4
Disconnect the
connector for the fan
motor [S70].
5
Release the lead wire
for the fan motor from
the hooks.
6
Disconnect the
connector for the gas
pipe thermistor [S91]
and for the liquid pipe
thermistor [S92].
[S91] : Gas pipe thermistor
(white)
[S92] : Liquid pipe thermistor
(red)
Step
Procedure
Points
(R9938)
Mounting plate
(R9939)
[S70]
(R9940)
(R9941)
[S92]
[S91]