![background image](http://html.mh-extra.com/html/daikin/2mxu40gv1b/2mxu40gv1b_service-manual_501101218.webp)
Indoor Unit
SiBE12-908
207
Removal Procedure
4
Detach the pivot from
the interlock shaft for
vertical blades by a flat
screwdriver.
5
Remove the swing
motor unit.
6
Detach the interlock
shaft from the swing
motor by a flat screw-
driver.
7
Remove the vertical
blade interlock by a flat
screwdriver.
Step
Procedure
Points
(R10623)
Vertical blade
Pivot
(R8126)
Swing motor unit
(R8127)
Interlock shaff
(R10331)
Vertical blade interlock