Main Functions
SiBE12-908
35
Function and Control
1.14 Table for Special Modes
A. Forced operation mode:
The buzzer beeps, and the timer and multi-colored indicator lamp illuminate.
Refer to page 53 for detail.
B. Easy diagnosis mode:
You can identify the error code in a quite simple way but some of the error codes do not appear
on the LCD.
Refer to the Check Method 1 on page 104 for detail.
1. Service check mode:
You can identify the error code for diagnosis.
Refer to the Check Method 2 on page 105 for detail.
(R9416)
Indoor [ON/OFF] 5~9 sec.
[CANCEL] 5 sec.
A Forced operation mode
B Easy diagnosis mode
• Indoor [ON/OFF]
• Left for 15 min.
• [CANCEL] 5 sec.
• Left for 60 sec.
Left for 60 sec.
Mode selection view:
Select with TEMP or button.
[MODE]
+
TEMP
+
TEMP
Service check mode
Trial operation mode
Pipe set mode
Pipe check mode
Drying mode
Humiditying airflow
rate setting mode
Monitor brightness
setting mode
1
2
3
4
5
6
7
5C
T
P5
PC
H
L
[MODE]
[MODE]
[MODE]
[MODE]
[MODE]
[MODE]
[MODE]
Diagnosis
Trial operation ON
Hose length setting
Hose length check
Hose Dry
operation ON
Airflow rate
setting
Monitor brightness
setting
[MODE] 2 sec.
• [MODE] 5 sec.
• Left for 60 sec.
• Operation OFF
• Left for 30 min.
• [MODE] 5 sec.
• Left for 60 sec.
• [MODE] 5 sec.
• Left for 30 min.
• [MODE] 5 sec.
• Left for 60 sec.
• [MODE] 5 sec.
• Left for 60 sec.
Nor
m
al
m
ode
Norm
al
m
ode