68
EXPERT 64EU rev.03
8. LIGHTS
8.1
Principle of Operation
The controller has four 0-10V outputs that can be used as variable light outputs.
Additional lights can also be connected to On/Off relays: these lights simply turn on
when the 0-10V light outputs are on. Refer to section 4.5 to enable the 0-10V light
outputs and to select the proper number of light programs; refer to section 4.6 to
assign On/Off light relays.
LIGHT PROGRAMS
:
A program can consist of up to 6 cycles that are daily performed to adjust the house’s
light intensity. The same light program is repeated daily up until another light pro-
gram replaces it. The user defines at what age each light program starts, following
the animals’ requirements. Up to 10 light programs can be used.
CYCLES:
Each light programs can contain up to 6 cycles. These cycles are used to change the
light intensity within a program.
GRAPHIC: 6 Cycle Light Program
CYCLE 1
CYCLE 2
CYCLE 3
CYCLE 4
CYCLE 5
CYCLE 6
stop
start
PROGRAM: 24H MAX.
GRAPHIC :
Light Cycles with Peaks
Standard
Intensity
LIGHT
INTENSITY
Start
Time
pe
ak
’s
su
nri
s
e
Min
pe
ak
’s
du
ra
ti
o
n
pe
ak’
s
s
uns
e
t
Peak Cycle
sunset
1 CYCLE
Stop
Time
Peak
Intensity
Time
sunrise