23
EXPERT 64EU rev.03
EXPERT 64EU
4.5
Output Setup
The following section shows how to enable the controller’s outputs according to the
requirements of your particular application. Normally, this setup only needs to be
done once for each program.
Pay attention. Some of the Installation Setup parameters are common to all
programs. Templates are available at the end of this manual to write down
the specific output settings of each program.
Select
12. Controller Setup
2. Output Setup*
* Only accessible from the installer mode (s. 4.2).
• Set the appropriate parameters amongst
the following:
• Number of Heaters:
Number of heating outputs.
Adjustable from 1 to 8 outputs. Refer
to the step 2 to increase the number of
heating outputs.
• Use Heater Lo/Hi Fire?
Select “Yes” to activate the heating out-
puts’ Lo & Hi fire option. This allows to
double the number of heating outputs.
Refer to sec. 7.1 for further information.
Common to all programs
• Use Variable Outputs?
Select “Yes” to enable 2 variable fan outputs.
Common to all programs
Variable 1-2 Start Speed during the Fan Stages:
Select the starting speed of the variable outputs; variable outputs are acti-
vated at this intensity at the beginning of a fan stage (stage 3 and higher).
Adjustable from 10 to 100%.
• Number of Fan Stages:
Number of fan stages. Adjustable from 1 to 15 stages.
Main Menu
11.
Alarm Log
12.
Controller Setup
Controller Setup
1.
Installation
2.
Output Setup
Output Setup
Number of Heaters
4
Use Heater Lo / Hi Fire
No
Use Variables ?
Yes
Var. 1 Stage Start Speed
10
Var. 2 Stage Start Speed
10
Number of Fan Stages
15
Number of Cooling Outputs
3
Number of Clock Outputs
24
Number of Clock Programs
4
Use Tunnel ?
Yes
Tunnel Curtain Control
SP
Use Tunnel Probe at Stage
3
Number of Inlets
12
Inlet Modules
IM-010/Pot.Ctrl
Number of 0-10V Outputs
4
0-10V Output 1 Mode
0-10V
0-10V Output 2 Mode
0-10V
0-10V Output 3 Mode
0-10V
0-10V Output 4 Mode
0-10V
0-10V Output 1 AssignmentVent. Fans
0-10V Output 2 Assignment
Lights
0-10V Output 3 Assignment
Heater
0-10V Output 4 AssignmentFollows V2
Number of Light Programs
10
Number of Relays
64
Exit: Press Back Change: Press Modify
Press to Select an Item
Summary of Contents for Integra EXPERT 64EU
Page 1: ...EXPERT 64EU Temperature Controller USER S MANUAL...
Page 2: ......
Page 100: ......
Page 101: ......
Page 102: ...M 890 00000 rev 03 REV 02...