64
EXPERT 64EU rev.03
EXPERT 64EU
6.5.2 Settings
Select
8. Start / Stop Temperature
3. Coolings*
* This menu is only available if cooling outputs are
activated (s.4.5).
• Set the following parameters.
Refer to the previous section to get further informa-
tion on these parameters.
Start Temperature:
Set the temperature at which the cool-
ing output starts operating using the
first timer. Adjustable from the set
point to 120°F (48.9°C).
Stop Temperature:
Set the temperature below which the
cooling output stops operating.
Adjustable from 0.5°F (0.3°C) below
the start temperature to -40°F (-40°C).
Maximum Temperature:
Set the temperature at which the cool-
ing output uses the second timer.
Adjustable from 0.5°F (0.3°C) above
the start temperature to 120°F
(48.9°C).
On Time 1 & 2:
Set both timers’ On and Off times to the desired values. Adjustable from 0 to
30 minutes.
Start / Stop at:
The cooling outputs are only activated within this time range. This allows to
deactivate it during night for instance.
Main Menu
8.
Start / Stop Temperature
9.
Advanced Settings
Start / Stop Temperature Settings
3.
Coolings
4.
Tunnel Curtain
Cooling Settings
Cooling 1
Start Temperature
85.0 °F
Stop Temperature
84.0 °F
Maximum Temperature
90.0 °F
On Time 1
1:00
(m:s)
Off Time 1
3:00
(m:s)
On Time 2
1:00
(m:s)
Off Time 2
3:00
(m:s)
Start at
6:00 A
Stop at
9:00 P
Cooling 2
Start Temperature
85.0 °F
Stop Temperature
84.0 °F
Maximum Temperature
90.0 °F
On Time 1
1:00 (m:s)
Off Time 1
3:00 (m:s)
On Time 2
1:00 (m:s)
Off Time 2
3:00 (m:s)
Start at
6:00 A
Stop at
9:00 P
Exit: Press BackChange: Press Modify