6 VENTILATION SETTINGS
6.1
Minimum Ventilation
6.1.1 Minimum Ventilation Timer
Minimum ventilation cycles are acti-
vated whenever the average room tem-
perature is below the start temperature
of fan stage 1. Running the fans even
though ventilation is not required for
reducing the room temperature is use-
ful to reduce the humidity level and
supply oxygen to the room. It also pre-
vents the fans from freezing in winter.
The minimum ventilation timer is composed of an On and Off time: fans keep running
during the On Time then returns to a stop during the Off Time.
Minimum ventilation cycles can be provided by the two variable fan outputs and/or
by chosen On/Off fans. All minimum ventilation fans share the same timer; this timer
can automatically be adjusted over time as the animals are growing by using a curve.
6.1.2 Minimum Ventilation Curves
Many minimum ventilation parameters can be automatically adjusted over time by us-
ing the minimum ventilation curve function. A curve is composed of 10 steps. Each
step specifies a parameter value and the day at which this parameter starts being used;
this day refers to the animal age. The controller automatically changes the parameter
value over time in a linear fashion between consecutive steps of the curve. When the
last step is reached, the parameter value is maintained until a new batch starts.
The following graphic illustrates a curve applied on the timer’s On Time: the fans’ On
Time, within the minimum ventilation cycles, automatically increases between
consecutive steps of the curve. Negative day values are used to prepare the house
before the animals’ arrival.
GRAPHIC:
Minimum Ventilation Timer
ON
ON TIME
OFF
OFF TIME
GRAPHIC:
Minimum Ventilation’s On Time Curve
FANS’
ON TIME
(SECONDS)
Animal age
(in days)
D-5
D10
D15
70
D20
65
D25
60
D30
55
D35
50
D40
45
40