24
EXPERT 64EU rev.03
EXPERT 64EU
• Number of Cooling Outputs:
Number of cooling outputs. Adjustable
from 0 to 3 outputs.
• Number of Clock Outputs:
Number of clock outputs. Adjustable
from 0 to 24 outputs.
• Number of Clock Programs:
Number of clock programs of each clock
output. Adjustable from 1 to 4 programs.
• Use Tunnel Curtain ?
Select “Yes” to
enable a curtain output.
• Tunnel Curtain Control:
Select whether the curtain is controlled
by the static pressure (SP) level or by
the average room temperature.
Only accessible if the tunnel curtain is enabled above.
The static pressure control can only be chosen if the
static pressure sensor is enabled (s. 4.4).
• Use Tunnel Probe at Stage:
The room temperature becomes defined by the tunnel curtain’s probe set when
this fan stage starts up. Select “None” to disable the curtain’s probe set.
Refer to section 4.8 to assign the temperature probes.
• Number of Inlets:
Adjustable from 0 to 12 air inlets.
Inlets type:
Select the type of inlet controller in use: a IM-010 Inlet Module or a Poten-
tiometer Feedback controller (Pot.Ctrl).
This menu is only accessible if the air inlets are activated above. Common to all program.
• Number of 0-10V Outputs:
Adjustable from 0 to 4 outputs.
0-10V Output Signal:
Select the signal used by each 0-10V output (0-10V or 10-0V).
Main Menu
11.
Alarm Log
12.
Controller Setup
Controller Setup
1.
Installation
2.
Output Setup
Output Setup
Number of Heaters
4
Use Heater Lo / Hi Fire
No
Use Variables ?
Yes
Var. 1 Stage Start Speed
10
Var. 2 Stage Start Speed
10
Number of Fan Stages
15
Number of Cooling Outputs
3
Number of Clock Outputs
24
Number of Clock Programs
4
Use Tunnel ?
Yes
Tunnel Curtain Control
SP
Use Tunnel Probe at Stage
3
Number of Inlets
12
Inlet Modules
IM-010/Pot.Ctrl
Number of 0-10V Outputs
4
0-10V Output 1 Mode
0-10V
0-10V Output 2 Mode
0-10V
0-10V Output 3 Mode
0-10V
0-10V Output 4 Mode
0-10V
0-10V Output 1 AssignmentVent. Fans
0-10V Output 2 Assignment
Lights
0-10V Output 3 Assignment
Heater
0-10V Output 4 AssignmentFollows V2
Number of Light Programs
10
Number of Relays
64
Exit: Press Back Change: Press Modify
Press to Select an Item