44
EXPERT 64EU rev.03
EXPERT 64EU
6.1.5.4
Curve Settings
A curve is composed of 10 steps. Each step specifies a parameter value and the day at
which this parameter starts being used; this day refers to the animal age. The follow-
ing menus allow to specify the parameter values for each step of the curve, for the
minimum ventilation functions that are based on the animal age.
Select
5. Minimum Ventilation
3. Curve Settings (10 Steps) *
* Only accessible if the minimum ventilation func-
tions are based on a curve or if the relay selection
changes over time. Refer to section 6.1.5.1
• Set the following parameters.
(Refer to the previous sections to get further infor-
mation on these parameters)
Curve Setting Status:
Select “Yes” to enable the curve;
select “No” to disable it.
Note that
curve parameters can only be modi-
fied while the curve is disabled.
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
Settings for :
Select the desired step of the curve. All following parameters are linked with
the selected step. Set these parameters separately for each step of the curve:
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
At Animal Age:
Select the age at which the selected curve step starts being used (in days).
Number of Fans per Group:
Select the number of fan relays that are simultaneously running within a fan group,
for the selected step of the curve.
Only accessible if the “Alternate Fan during On Time” and “Curve Settings” functions are enabled in sec. 6.1.5.1.
Number of Groups per On Time:
Select the number of fan groups that are successively enabled during one
On Time of the minimum ventilation cycles, for the selected step of the curve.
Only accessible if the “Alternate Fan during On Time” and “Curve Settings” functions are enabled in sec. 6.1.5.1.
Main Menu
5.
Minimum Ventilation
6.
Inlet Setup
7.
Light Settings
8.
Start / Stop Temperature
9.
Advanced Settings
10.
Select Program
11.
Alarm Log
12.
Controller Setup
Submenu: Press Enter
Press
to Select an Item
Minimum Ventilation
2.
Current Selected Fan Relays
3.
Curve Settings (10 Steps)
Min. Vent. Curve Settings
Curve Setting Status > Off
-----------------------------------
Settings for Step 1
-----------------------------------
At Animal Age :
1 Days
Nbr Fans per Group:
3 Fans
Nbr.Groups per OnTime :
10 group
Fan Group Run Time : 2:00 (m:s)
Total On Time : 2:00 (m:s)
Off Time : 3:00 (m:s)
Variable 1 Speed :
10 %
Variable 2 Speed :
10 %
Exit: Press Back
Change: Press Modify
Press to Select an Item