Main Menu
6.
Inlet Setup
7.
Light Settings
Inlet Setup
1.
Probe Assignment
2.
Opening
3.
Temperature Compensation
Exit: Press Back Submenu: Press Enter
Press
to Select an Item
Inlet Compensation
Inlet 1 Opening Comp.
5 %/°F
Inlet 2 Opening Comp.
5 %/°F
Inlet 3 Opening Comp.
5 %/°F
Inlet 4 Opening Comp.
5 %/°F
Inlet 5 Opening Comp.
5 %/°F
Inlet 6 Opening Comp.
5 %/°F
Inlet 7 Opening Comp.
5 %/°F
Inlet 8 Opening Comp.
5 %/°F
Inlet 9 Opening Comp.
5 %/°F
Inlet 10 Opening Comp.
5 %/°F
Inlet 11 Opening Comp.
5 %/°F
Inlet 12 Opening Comp.
5 %/°F
Exit: Press Back
Change: Press Modify
Press to Select an Item
6.4.2.4
Inlet Settings: Temperature Compensation
Select
6. Inlet Setup
3. Temperature Compensation
• Set the following parameters.
(Refer to section 6.4.1.2 to get further informa-
tion on these parameters)
Inlet x Comp.:
Set the compensation value for each
activated air inlet. Adjustable from
0 to 100%/°F.
6.4.2.5
Inlet Settings: Static Pressure Compensation
Select
6. Inlet Setup
4. Static Pressure Compensation*
* Only accessible if a static pressure sensor is en-
abled (sec. 4.4).
• Set the following parameters.
(Refer to section 6.4.1.2 to get further information
on these parameters)
Low Set Point:
The static pressure compensation
starts when the pressure level
decreases below this level.
High Set Point:
The static pressure compensation starts when the pressure level increases beyond
this level.
Compensation Delay:
The high or low pressure condition must be maintained for this time limit
before the inlet compensation starts. Adjustable from 0 to 900 seconds.
Inlet x Opening Compensation:
Set the compensation value for each activated air inlet. Adjustable from 0 to
10 %/ 0.01 “WC
Main Menu
6.
Inlet Setup
7.
Light Settings
Inlet Setup
3.
Temperature Compensation
4.
Static Pressure Compensation
Inlet Static Pressure Compensation
Low Set Point
.00 WC
High Set Point
.10 WC
Compensation Delay
30 sec
Inlet Opening Comp. (% / 0.01WC)
Inlet 1
0 %
Inlet 2
0 %
Inlet 3
0 %
Inlet 4
0 %
Inlet 5
0 %
Inlet 6
0 %
Exit: Press Back
Change: Press Modify
Press to Select an Item