5.1.2 Set Point Curve
The set point curve allows an automatic adjustment of the target room temperature over
time.
The set point changes using 10 steps. Each step specifies a day number and a target
temperature for that day. These steps are based on the animal age. Once the 10 steps
are defined, the curve must be activated. The controller then starts changing the
temperature set point every hour in a linear fashion between consecutive steps of the
curve. When the last step is reached, the temperature set point for that day is
maintained until the animal age is set to Off or until the user changes it manually.
If a night set point is used:
A curve can also be defined to adjust the night set point over time. The night curve is
set separately from the day curve.
NOTE
: Certain restrictions apply to reduce the risk of errors:
- The highest possible day number is 450.
- Decreasing day numbers is not allowed.
- All ten steps must be specified. If you don't need ten different steps,
repeat the last temperature for each unnecessary step.
GRAPHIC: Set Point Curve
SET POINT (°F)
DAYS
DAY -5
78
76
DAY 10
74
DAY 15
72
DAY 20
70
DAY 25
68
DAY 30
66
DAY 35
64
DAY 40
62
60
DAY 0