COPIER (Service mode for printer) > OPTION (Specification setting mode) > NETWORK
FTPMODE
1
Set of FTP print default operation mode
Detail
To set the default operation mode of FTP print.
Switch the default operation mode between ASCII mode and BIN mode in accordance with user's
environment.
Use Case
At installation
Adj/Set/Operate Method
1) Enter the setting value, and then press OK key.
2) Turn OFF/ON the main power switch.
Display/Adj/Set Range
0 to 1
0: ASCII mode, 1: BIN mode
Default Value
0
SSLMODE
2
Setting of HTTP/HTTPS port open/close
Detail
*Operation on this item is restricted by the setting of [Restrict Service Representation Access].
To set whether to open or close HTTP/HTTPS port.
When 1 is set while [Use HTTP] is ON and [Use TLS] is OFF in Settings/Registration menu, HTTP
port is opened whereas HTTPS port is closed.
When 2 is set while both [Use HTTP] and [Use TLS] are ON in Settings/Registration menu, HTTP
port is closed whereas HTTPS port is opened.
Use Case
When limiting the port to open because of security concern
Adj/Set/Operate Method
1) Enter the setting value, and then press OK key.
2) Turn OFF/ON the main power switch.
Display/Adj/Set Range
0 to 2
0: Normal, 1: Open HTTP port (80/8000) only, 2: Open HTTPS port (443/8443) only
Default Value
0
Additional Functions
Mode
Preferences> Network> TCP/IP Settings> Use HTTP
Management Settings> License/Other> MEAP Settings> Use TLS
SSLSTRNG
2
Allow weak encryption algorithm for SSL
Detail
To set whether to allow using weak encryption algorithm for SSL.
When 1 is set, weak encryption algorithm cannot be used.
Use Case
When prohibiting weak encryption algorithm because of security concern
Adj/Set/Operate Method
1) Enter the setting value, and then press OK key.
2) Turn OFF/ON the main power switch.
Display/Adj/Set Range
0 to 1
0: Normal mode, 1: Secured mode (TLS_RSA_WITH_RC4_128_SHA and TLS_RSA_WITH_
RC4_128_MD5 are not used)
Default Value
1
NW-WAIT
2
Set connect wait at deep sleep recovery
Detail
To set whether to send wakeup notice after the time set in Settings/Registration menu has elapsed
when recovering from deep sleep.
When 0 is set, wakeup notice is sent after "Waiting Time for Connection at Startup" has elapsed.
When 1 is set, wakeup notice is sent when the machine becomes ready for communication.
Use Case
When a failure of the device management tool occurs
Adj/Set/Operate Method
1) Enter the setting value, and then press OK key.
2) Turn OFF/ON the main power switch.
Display/Adj/Set Range
0 to 1
0: Wait, 1: Not wait
Default Value
0
Additional Functions
Mode
Preferences> Network> Waiting Time for Connection at Startup
8. Service Mode
777
Summary of Contents for imageRUNNER ADVANCE C3500 III Series
Page 1: ...Revision 2 1 imageRUNNER ADVANCE C3500 III Series Servie Manual ...
Page 23: ...Safety Precautions Laser 2 Power Supply Lithium Battery 3 Toner Safety 4 Notes on works 4 ...
Page 28: ...Product Overview 1 Product Lineup 7 Specifications 11 Parts Name 34 ...
Page 153: ...Periodical Service 3 Consumable Parts List 132 Cleaning Parts 136 ...
Page 158: ...Cleaning Parts 15 9 14 13 8 4 16 17 5 3 6 7 1 2 12 10 11 15 16 3 Periodical Service 136 ...
Page 211: ...2 Remove the HDD Unit 1 3 Hooks 2 1 Screw 3 1x 2 2 3 4 Parts Replacement and Cleaning 189 ...
Page 249: ...2 3 1x 4 Parts Replacement and Cleaning 227 ...
Page 306: ...Troubleshooting 6 Initial Check 285 Test Print 286 Troubleshooting Items 291 Debug Log 304 ...
Page 345: ...Error Jam Alarm 7 Outline 324 Error Code 328 Error Code FAX 466 Alarm Code 469 Jam Code 517 ...
Page 1029: ...1 2 2x 3 4 NOTE The removed CR BOX Upper Unit will be used in step 14 9 Installation 1007 ...
Page 1050: ...Installation Procedure Installing the Equipment 1 2 3 9 Installation 1028 ...
Page 1052: ...8 Turn ON the main power switch 9 Installation 1030 ...
Page 1063: ...2 2x 1x 3 1x 1x 1x 4 1x 1x NOTE The removed screw will be used in step 5 9 Installation 1041 ...
Page 1088: ...4 6x 5 4x 6 7 NOTE Do not close the Wire Saddle 1x 8 9 Installation 1066 ...
Page 1091: ...14 15 16 17 2x 18 9 Installation 1069 ...
Page 1104: ...2 2x 3 Connect the power plug to the outlet 4 Turn ON the power switch 9 Installation 1082 ...
Page 1112: ...When Installing the USB Keyboard 1 9 Installation 1090 ...
Page 1114: ...Installation Procedure Removing the Covers 1 2x 2 1x 3 2x 9 Installation 1092 ...
Page 1115: ... Installing the Removable HDD Kit 1 2 3x 4x 9 Installation 1093 ...
Page 1119: ...11 12 1x 13 NOTE Use the screw removed in step 3 1x 9 Installation 1097 ...
Page 1120: ...14 3x 4x Installing the Covers 1 2 2x 3 1x 9 Installation 1098 ...
Page 1123: ...Installation Procedure Removing the Covers 1 2x 2 1x 3 2x 9 Installation 1101 ...
Page 1127: ...8 3x 4x Installing the Covers 1 2x 2 1x 9 Installation 1105 ...
Page 1134: ...2 On the screen shown below press Change and then Detailed Settings 3 9 Installation 1112 ...
Page 1140: ...Installation procedure Remove the Control Panel 1 2 2x 3 4 2x 5 2x 9 Installation 1118 ...
Page 1141: ...6 2x 7 4x 8 3x 9 10 9 Installation 1119 ...
Page 1142: ...11 12 6x 13 2x 14 9 Installation 1120 ...
Page 1143: ... Installing the NFC Kit 1 2 2x 3 1x TP M3x4 4 1x 9 Installation 1121 ...
Page 1144: ... Installing the Control Panel 1 2 2x 3 6x 4 9 Installation 1122 ...
Page 1145: ...5 6 3x 7 4x 8 2x 9 10 2x 9 Installation 1123 ...
Page 1146: ...11 2x 12 13 2x 14 9 Installation 1124 ...
Page 1154: ...14 4x Installing the Relay PCB 1 1x 1x TP M3x6 1x 2 1x 1x 9 Installation 1132 ...
Page 1155: ...3 4 2x 3x 5 4x 6 9 Installation 1133 ...
Page 1162: ... Installing the Relay PCB 1 1x 1x TP M3x6 1x 2 1x 1x 9 Installation 1140 ...
Page 1163: ...3 4 2x 3x 5 4x 9 Installation 1141 ...
Page 1180: ...6 1x 7 8 5x M3x6 9 Installation 1158 ...
Page 1200: ...2 3 2x 4 1x 9 Installation 1178 ...