Service Mode > COPIER > FUNCTION > INSTALL
Service Mode > COPIER > FUNCTION > INSTALL
COPIER>FUNCTION>INSTALL
CNT-DATE
Set counter send start date to SC server
Lv.1 Details
To set the year, month, date, hour and minute to send counter
information to the sales company’s server.
This is displayed only when the non-Canon-made extension function
of the Embedded-RDS is available.
Use case
When the non-Canon-made extension function of the Embedded-RDS
is available
Adj/set/operate method 1) Enter the setting value, and then press OK key.
2) Turn OFF/ON the main power switch.
Display/adj/set range
YYYYMMDDHHMM (12 digits)
YYYY: Year, MM: Month, DD: Date, HH: Hour, MM: Minute
Default value
000000000000
Supplement/memo
Embedded-RDS: Function to send device information such as the
device counter, failure, and consumables to the sales company’s
server via SOAP protocol
CNT-INTV
Set counter send interval to SC server
Lv.1 Details
To set the interval of sending counter information to the sales
company’s server in a unit of one hour.
This is displayed only when the non-Canon-made extension function
of the Embedded-RDS is available.
Use case
- When restarting potential control after execution of COPIER>
OPTION> IMG-FIX> PO-CNT
- When the D-max control condition is changed
Adj/set/operate method 1) Enter the setting value, and then press OK key.
2) Turn OFF/ON the main power switch.
Display/adj/set range
1 to 168 (= 1 week)
Unit
1 hour
Default value
24
Supplement/memo
Embedded-RDS: Function to send device information such as the
device counter, failure, and consumables to the sales company’s
server via SOAP protocol
COPIER>FUNCTION>INSTALL
INISET-4
All colors Dev Units initial instal mode
Lv.1 Details
To automatically execute operation necessary for initial installation of
the Developing Units for all colors.
1. Idle rotation of the Developing Unit (including automatic take-up of
the developer sealing)
2. Dark current correction of the Registration Patch Sensor and light
intensity adjustment
3. Initialization of the Toner Density Sensors for all colors
4. Primary transfer ATVC control
5. Initialization of the Registration Patch Sensor
6. Cleaning of the Secondary Transfer Outer Roller
7. Reset of the Developing Unit counter
Use case
When replacing the Developing Units for all colors
Adj/set/operate method Select the item, and then press OK key.
Caution
Use this item only when replacing Developing Units for 4 colors
simultaneously.
Display/adj/set range
During operation: xxx second (remaining time), At normal termination:
OK, At abnormal termination: NG
Required time
180 sec
Related service mode COPIER> FUNCTION> INSTALL> INISET-Y/M/C/K
INISET-K
Exe of Dev Unit (Bk) initial install mod
Lv.1 Details
To automatically execute operation necessary for initial installation of
the Developing Unit (Bk).
1. Idle rotation of the Developing Unit (including automatic take-up of
the developer sealing)
2. Dark current correction of the Registration Patch Sensor and light
intensity adjustment
3. Initialization of the Toner Density Sensor (Bk)
4. Primary transfer ATVC control
5. Initialization of the Registration Patch Sensor
6. Cleaning of the Secondary Transfer Outer Roller
7. Reset of the Developing Unit counter
Use case
When replacing the Developing Unit (Bk)
Adj/set/operate method Select the item, and then press OK key.
Caution
When installing the machine or replacing the Developing Unit of other
color, do not use this item.
Display/adj/set range
During operation: xxx second (remaining time), At normal termination:
OK, At abnormal termination: NG
Required time
180 sec
Related service mode COPIER> FUNCTION> INSTALL> INISET-Y/M/C/4